Télécharger Imprimer la page

Hilti DCH 300-X Mode D'emploi page 16

Masquer les pouces Voir aussi pour DCH 300-X:

Publicité

Les langues disponibles

Les langues disponibles

The voltage provided by the power source must remain within +5 % and –15 % of the tool's rated
voltage.
Frequency: 50 to 60 Hz (never above 65 Hz)
The power source must be equipped with automatic voltage regulation and starting boost.
ATTENTION
Risk of damage Switching on or switching off other power tools or appliances connected to the generator
or transformer may cause undervoltage and/or overvoltage peaks, resulting in damage to the cutter.
▶ Never operate other power tools or appliances from the generator or transformer at the same time. Where
applicable, use a generator or transformer designed for simultaneous operation of the cutter and vacuum
cleaner.
5.1.2
Use of extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Use only extension cords of a type approved for the application and with conductors of adequate
cross-section. Otherwise the performance of the appliance may be affected and the cord may overheat.
Regularly check the extension cord for damage.
Replace damaged extension cords.
When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Recommended minimum conductor cross-sections and maximum power cord lengths for 120V sup-
ply voltage
Power cord
Conductor cross-section
Conductor cross-section
Power cord length
Power cord length
5.1.3
Checking the portable residual current device (PRCD)
DCH 300–X
1. Plug the power tool's supply cord into a grounded power outlet.
2. Press the ON button on the portable residual current device.
◁ The indicator shows.
3. Press the Test button on the portable residual current device.
◁ The indicator goes out.
▽ The indicator does not goes out.
▶ Do not use the power tool. Have it repaired by a qualified specialist using genuine Hilti spare
parts.
5.2
Fitting a diamond cutting disc
M16 × 1.5 clamping nut
@
Ø 60 mm clamping flange
;
Diamond cutting disc
=
1. Observe the instructions concerning correct selection of suitable cutting discs → page 9 and the
dimension and format specifications for diamond cutting discs → page 9.
2. Disconnect the mains plug from the power outlet.
3. Clean the clamping flange and the clamping nut.
10
English
Printed: 23.10.2018 | Doc-Nr: PUB / 5459266 / 000 / 00
AWG 16
AWG 14
1,31 mm²
2,08 mm²
2,58 kcmil
4,11 kcmil
25 m
30 m
75 ft
100 ft
3
Ø 60 mm reversible flange
%
Arbor
&
AWG 12
AWG 10
3,31 mm²
5,26 mm²
6,53 kcmil
10,4 kcmil
50 m
100 m
150 ft
250 ft
2149877
*2149877*

Publicité

loading

Ce manuel est également adapté pour:

Dch 300