Maintenance For The Squeegee
To remove the squeegee, follow this procedure:
1. Remove the squeegee assembly by loosening the two knobs that attach
the squeegee to the machine. Pull the squeegee assembly off. See
fi gure 25.
2. Inspect the squeegee blades.
3. If the blades are worn, unclamp bands and turn the blade so that a new
edge is in the wiping position (see fi gures 25A and 25B).
4. Reinstall squeegee assembly on the machine.
Adjusting Squeegee Tilt
The tilt of the squeegee causes the rear blade to raise up in the center or
on the ends, depending on which direction the tilt is changed. Turn
the adjusting screw clockwise or counterclockwise (see fi gure 26), to
achieve uniform squeegee blade fl are.
WARNING:
Maintenance and repairs must be done by au-
thorized personnel only.
WARNING:
Electrical repairs must be done by authorized
personnel only.
Maintenance Procedures Must Be Done :
Contact a Clarke Authorized Service Center
to perform these procedures.
Every 500 hrs (heavy) 1000 hrs (normal)
1. Check the carbon brushes in the electric motors.
2. Clean the battery terminals and connectors. Make sure all of the battery
connections are tightened correctly.
3. Check all of the switches, controls, valves, hoses and gaskets.
4. Check and remove debris from the transaxle hubs.
Every 500 hrs (BOOST Only)
1. Replace the rubber isolators (see Brush Head Assembly Parts List sec-
tion). The rubber isolators are considered wear items and must be re-
placed between 500 hrs (heavy) and 1000 hrs (normal).