length; -Minimum possible bends (maximum angle of bend: 90°); -certified
material (according to local, building and fire regulations); and as smooth as
possible inside. It is also advisable to avoid any drastic changes in duct
cross-section (recommended diameter: 150mm).
For recirculation version, please consider some outlets for clean air returns
into the room.
Fitting under wall unit
1. Before fixing the hood to the unit, drill a hole of 165mm diameter for
φ150mm exhaust Ducting or 135mm for φ120mm exhaust Ducting in
the wall unit.
2. In any case, check the position of the power outlet and consider where
the power cable will run, since a hole might have to be made in the wall
unit to accommodate it.
3. Unscrew the 2 visible screws located on hood of both inner size of filter
frame and remove the face plate. The 6 mounting holes around the unit
are then accessible.
4. Lift the range hood and fit through the opening of the cabinet. Secure
unit by using 6 long mounting screws.