Wavetek Meterman 23XT Manuel D'utilisation page 15

Table des Matières

Publicité

❶ Turn off power to the resistance to be measured and discharge capacitors. Any
voltage present during a resistance measurement will cause inaccurate readings.❷
Connect red test lead to V•Ω Input and black test lead to COM Input. ❸ Set
Function/Range Switch to the desired Ω position. ❹ Connect test leads to resistance or
circuit to be measured. š Read resistance value on Digital Display. Open circuits will be
displayed as an overload condition.
Note: For low resistance values, measure resistance of test leads first by contacting
probe tips, and deduct this value from actual measurement.
Note for 23/27XT: The 2000MΩ range has a fixed 10-count offset in the reading. For
example, when measuring 1100MΩ, the display reads 1110. The 10 residual must be
subtracted to obtain the actual value of 1100MΩ.
D • Widerstandsmessung (siehe Fig. 3)
❶ Jede Spannung vom Widerstand abschalten und Kondensatoren entladen. Eine
am Widerstand anliegende Spannung würde das Resultat verfälschen. ❷ Rotes
5
ON/OFF
H
20m
2m
TTL
LOGIC
CMOS
2000
M
20M
V-
2
RESISTANCE MEASUREMENT (See Fig. 3)
k
HI/LO
MAX
DC/AC
20M
1000
Hz
20
750
200
2
20
200m
2
200m
3
2M
200k
2
20k
20
2k
2000
200
Cx
Lx
COM
mA Cx Lx 20A
CAT.
II
200mA MAX
FUSED
MAX
MAX
1000V
20A/30sec
750V
FUSED
V
A
200m
20m
10A
2m
200
2n
20n
F
27XT
- 13 -
Fig. 3
1
4
red
rot
roja
rouge

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Meterman 25xtMeterman 27xtMeterman 28xt

Table des Matières