Télécharger Imprimer la page

Craftsman 919.728001 Mode D'emploi page 27

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
PROBLEM
Motor will not
Motor overload protection
run.
switch has tripped.
Tank pressure exceeds
pressure switch "cut-in"
pressure.
Check valve stuck open.
Extension cord is wrong
length or gauge.
Possible defective motor
or starting capacitor.
Paint spray on internal
motor parts.
Pressure release valve on
pressure switch has not
unloaded head pressure.
Fuse blown, circuit breaker
tripped.
CAUSE
Let motor cool off and
overload switch will
automatically reset.
Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.
Remove and clean, or replace.
Check for proper gauge wire
and cord length.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician. Do not
operate the compressor in
the paint spray area. See
flammable vapor warning.
Bleed the line by pushing the
lever on the pressure switch to
the "Off" position; if the valve
does not open, replace switch.
1.
2.
3.
4.
27 - ENG
CORRECTION
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a
fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.
Check for proper fuse. You
should use a time delay
fuse.
Check for low voltage
conditions and/or proper
extension cord.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
A15256