Power button
Power switch on/off.
LED display
Shows the set temperature in °C or °F("°F" no display for some models) and
the Auto-timer settings. While on DRY and FAN modes, it shows the room
temperature.
Shows Error codes and protection code:
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (On some models).
E4-Display panel communication error.
EC-Refrigerant leakage detection malfunction (On some models).
P1-Bottom tray is full--Connect the drain hose and drain the collected water
away.If protection repeats,call for service.
Note : When one of the above malfunctions occurs, turn off the unit, and
check for any obstructions. Restart the unit, if the malfunction is still
present, turn off the unit and unplug the power cord. Contact the manu-
facturer or its service agents or a similar qualified person for service.
4.2 Operation instructions :
COOL operation
- Press the "MODE" button until the
"COOL" indicator light comes on.
Press the ADJUST buttons " " or
-
" " to select your desired room
temperature.
ture can be set within a range of
17°C~30°C/62°F~88°F(or 86°F).
- Press the "FAN SPEED" button to
choose the fanspeed.
FAN operation
- Press the "MODE" button until the"FAN " indicator light comes on.
- Press the "FAN SPEED" button on the remote controller to choose the fan
speed. The temperature can not be adjusted.
- Do not put the duct to window.
The
tempera-
DRY operation
- Press the "MODE" button until the
"DRY" indicator light comes on.
- The fan speed or the temperature
cannot be adjusted. The fan motor
operates at LOW speed.
Note : Keep windows and doors
closed for the best dehumidifying
effect. Do not put the duct to win-
dow.
ENG