Included
AC Power
Power Linking
AC Plug
Replacing the
Fuse
DMX Linking
DMX
Connection
Master/Slave
Connection
All manuals and user guides at all-guides.com
·
Q-Wash™ 419Z-LED
·
Power input cord
·
2 Omega brackets
This product has an auto-ranging power supply that can work with
an input voltage range of 100 to 240 V, 50/60 Hz.
You can link up to 5 Q-Wash™ 419Z-LED products at 120 V or
9 at 230 V. Never exceed this number. Power linking cords can be
purchased separately.
Connection
AC Live
AC Neutral
AC Ground
Green/Yellow
Disconnect this product from power.
Using a Phillips #2 head screwdriver, unscrew the fuse holder
1.
cap from the housing.
2.
Using the same type and rating, remove the blown fuse and
replace it with a good fuse.
3.
Screw the fuse holder cap back into place and reconnect power.
The Q-Wash™ 419Z-LED will work with a DMX controller using a
regular DMX serial connection. For more information on how to
configure for DMX operation, see DMX Primer from
www.chauvetpro.com.
The Q-Wash™ 419Z-LED uses a regular DMX data connection for
its DMX personalities: PERSON1, PERSON2, PERSON3,
PERSON4, and PERSON5. See the user manual to connect and
configure for DMX operation.
The Q-Wash™ 419Z-LED uses the DMX data connection for its
Master/Slave mode. See the user manual to connect and configure
for master/slave operation.
Q-Wash™ 419Z-LED QRG
·
Safety cable
·
Warranty card
·
Quick Reference Guide
Wire (U.S.)
Wire (Europe)
Black
Brown
White
Green/Yellow
3
Screw Color
Yellow/Brass
Blue
Silver
Green