Remplacement of the voltage cable
The connection of the voltage cable to the
appliance's terminal block is of type "Y". This means
that its replacement requires the specific equipment
of a technician. In this case, only cable type
H05V2V2-F T90 must be used. The cable section
must be suitable to the voltage and the working
temperature. The yellow/green earth wire must be
approximately 2 cm. longer than the phase wires (Fig.
4-a).
To open the terminal block and reach the
terminals, proceed as follows:
insert the point of a screwdriver into the visible
protrunding part of the terminal block;
exert a light pressure and lift (Fig. 4-b)
14
Fig. 4-a
Fig. 4-b
Neutral
Earth
(yellow/green))