Installation - for contractors
Temperature setback via control cable
To reduce the temperature set at the thermostat (by
3.5 °C), the black control cable is activated via an exter-
nal electronic contact (e.g. a time switch).
Control cable connected to a control unit
You can connect the appliance to any control unit that
issues the following waveforms as control signals:
Command
Oscilloscope
No power
Complete oscil-
lation 230 V
Semi-oscillation
negative -230 V
Semi-oscillation
positive +230 V
10. Commissioning
10.1 Initial start-up
When the appliance is first started up, it may give off a
smell. Make sure that the room is adequately ventilated
(with a partially open window, for example).
10.2 Appliance handover
» Explain the functions of the appliance to the user.
» In particular, draw attention to the safety instructions.
» Hand over the operating and installation instructions
to the user.
11. Shutdown
» Move the sliding switch to the "appliance off"
position.
12. Troubleshooting
Note
The power cable may only be replaced by a qualified
contractor using original spare parts supplied by us.
13. Specification
13.1 Dimensions and connections
a20 Appliance
b01 Power connection
i13
Wall mounting bracket
16
All manuals and user guides at all-guides.com
Operating
Heating temper-
mode
ature
Comfort
Subject to the set-
mode
ting of the tempera-
ture control knob
Setback
Approx. 3.5 °C
mode
lower than the tem-
perature set on the
temperature control
knob
Frost pro-
Frost protection
tection
temperature (ap-
prox. 6 °C)
Appliance
None
OFF
a20
Width
Entry electrical cables
Horizontal hole spacing
13.2 Data table
Electrical data
Power supply
Connected load
Dimensions
Height
Depth
Width
Weights
Weight
Versions
Colour
Frost protection setting
IP rating
Safety category
Values
Setting range
100
b01
KLE 502
189771
1/N ~ 230/240 V 1/N ~ 230/240 V
kW
0.5
mm
250
mm
100
mm
662
kg
4
White, RAL 9016
°C
7
IP24
II
°C
10-30
i13
KLE 502
mm
665
mm
210
KLE 1002
189772
1
250
100
1110
5.9
White, RAL
9016
7
IP24
II
10-30
KLE 1002
1110