11) REPLACING THE INJECTORS
The burners can be adapted to different types of gas by
mounting injectors suited to the type of gas in question. To do
this, first remove the burner tops using a wrench "B". Now
unscrew injector "A" (see fig. 15) and fit a injector corresponding
to the utilized type of gas in its place.
It is advisable to strongly tighten the injector in place.
After the injectors have been replaced, the burners must
be regulated as explained in paragraphs 10. The technician
must reset any seals on the regulating or pre-regulating
BURNER ARRANGEMENT ON THE HOT PLATE
BURNERS
N°
DENOMINACIÓN
1
ULTRA RAPID
2
RAPID
3
SEMIRAPID
4
AUXILIARY
15
FISH
All manuals and user guides at all-guides.com
CONVERSIONS
TABLE
NORMAL
PRESSURE
GAS
mbar
28 - 30
G30 - BUTANE
G31 - PROPANE
37
20
G20 - NATURAL
G30 - BUTANE
28 - 30
G31 - PROPANE
37
G20 - NATURAL
20
28 - 30
G30 - BUTANE
G31 - PROPANE
37
20
G20 - NATURAL
G30 - BUTANE
28 - 30
G31 - PROPANE
37
G20 - NATURAL
20
G30 - BUTANE
28 - 30
G31 - PROPANE
37
G20 - NATURAL
20
FIG. 15
30
devices and affix the label corresponding to the new gas
regulation on the appliance instead of the already existing
one. This label is supplied in the packet containing the
spare injectors.
The envelope with the injectors and the labels can be
included in the kit, or at disposal to the authorized
customer Service Centre.
For the sake of convenience, the nominal rate table also lists the
heat inputs of the burners, the diameter of the injectors and the
working pressures of the various types of gas.
NORMAL
RATE
g/h
l/h
225
221
295
204
200
267
127
125
167
73
71
95
204
200
267
INJECTOR
NOMINAL
DIAMETER
HEAT IMPUT(W)
1/100 mm
Min.
Max.
90
1400
3100
90
1400
3100
121 Y
1400
3100
83
800
2800
83
800
2800
117 S
800
2800
65
500
1750
65
500
1750
97 Z
500
1750
50
400
1000
50
400
1000
72 X
400
1000
83
1400
2800
83
1400
2800
117 S
1400
2800