PROBLEM
Pressure switch does
Excessive tank
not shut off motor when
pressure - safety
compressor reaches "cut-
valve pops off.
out" pressure.
Pressure switch "cut-out"
too high.
Air leaks at
Tube fittings are not tight
fittings.
enough.
Defective air tank.
Air leaks in air
tank or at air
tank welds.
Air leaks
Leaking seal.
between head
and valve plate.
Air leak from
Possible defect in safety
safety valve.
valve.
Possible defect in safety
Knocking Noise.
valve.
TROUBLESHOOTING
CAUSE
17 - ENG
CORRECTION
Move On/Auto/Off lever to
the "Off" position, if the
outfit does not shut off
contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. Do Not
Overtighten.
Air tank must be replaced.
Do not repair the leak.
Do not
drill into,
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.
Contact a Trained Service
Technician.
Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.
Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.