Télécharger Imprimer la page

STA-RITE SG12 Serie Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

MOTOR SPECIFICATIONS
Model
Voltage/
Number
HP
Phase
SG12200225M
2
208-230/1
SG12200325M
2
208-230/460/1
SG13200225M
2
208-230/1
SG13200325M
2
208-230/460/3
SGC12200225M
2
208-230/1
SGC12200325M
2
208-230/460/3
SGC13200225M
2
208-230/1
SGC13200325M
2
208-230/460/3
SGC20300225M
3
208-230/1
SGC20300325M
3
208-230/460/3
SGC20500225M
5
208-230/1
SGC20500325M
5
208-230/460/3
SGC20750325M
7.5
208-230/460/3 24.3-22.0/11.0
PERFORMANCE CHART
GPM at Total Feet (M)
Model
20(6)
50(15)
Number
Capacity Gallons/Minute(LPM)
SG12200225M
44(167)
36(136)
SG12200325M
44(167)
36(136)
SG13200225M
55(208)
45(170)
SG13200325M
55(208)
45(170)
SGC12200225M
44(167)
36(136)
SGC12200325M
44(167)
36(136)
SGC13200225M
55(208)
45(170)
SGC13200325M
55(208)
45(170)
SGC20300225M
104(394) 76(288)
SGC20300325M
104(394) 76(288)
SGC20500225M
116(439) 108(409) 80(303)
SGC20500325M
116(439) 108(409) 80(303)
SGC20750325M
168(636) 150(568) 120(454) 86(326)
Table I: Electrical Nameplate Data
Model
HP
SG12200225M
2
SG12200325M
2
208-230/460/60/3
SG13200225M
2
SG13200325M
2
208-230/460/60/3
SGC12200225M
2
SGC12200325M
2
208-230/460/3
SGC13200225M
2
SGC13200325M
2
208-230/460/60/3
SGC20300225M
3
SGC20300325M
3
208-230/460/60/3
SGC20500225M
5
SGC20500325M
5
208-230/460/60/3
SGC20750325M
7.5 208-230/460/60/3
* Motor RPM is 3450.
NOTICE: Motors rated at 230V/60Hz/1ø may overload if operated on 208 volts. Consult factory before attempting to operate
single phase motors on 208 volts.
All manuals and user guides at all-guides.com
Motor
Minimum
Max. Load
Circuit
Amps
Req.(Amp)
12.0
20
6.6-6.0/3.0
10/10
14.0
30
7.1-6.4/3.2
10/10
12.0
20
6.6-6.0/3.0
10/10
14.0
30
7.1-6.4/3.2
10/10
28.0
50
15.5-14.0/7.0
20/10
34.0
60
20.0-18.0/9.0
30/20
30/20
No Flow at
80(24)
110(34) Height Shown
Below Ft. (M)
12(45)
85(26)
12(45)
85(26)
28(106)
8(30)
116(35)
28(106)
8(30)
116(35)
12(45)
85(26)
12(45)
85(26)
28(106)
8(30)
116(35)
28(106)
8(30)
116(35)
15(57)
84(25.6)
15(57)
84(25.6)
18(68)
116(35)
18(68)
116(35)
150(46)
Volts/Hz/Ph
Amps
230/60/1
12.0
6.6-6.0/3.0
230/60/1
14.0
7.1-6.4/3.2
230/60/1
12.0
6.6-6.0/3.0
230/60/1
14.0
7.1-6.4/3.2
230/60/1
28.0
15.5-14.0/7.0
230/60/1
34.0
20.0-18.0/9.0
24.3-22.0/11.0
PIPING DIMENSIONAL GUIDE
Basin
Discharge
Depth
Height
Figure 1: Basin Dimensions
Dimension
Vertical Discharge Pipe Length
(= Disch. Pipe Height – X)
Locking Rail Length
( = Basin Depth – Y)
Guide Rail Length
(= Basin Depth – Z)
Cut Length of Base Pipe:
Minimum Basin Diameter (Simplex):
Minimum Basin Diameter (Duplex):
Dimension
Vertical Discharge Pipe Length
(= Disch. Pipe Height – X)
Locking Rail Length
( = Basin Depth – Y)
Guide Rail Length
(= Basin Depth – Z)
Cut Length of Base Pipe:
Minimum Basin Diameter (Simplex):
Minimum Basin Diameter (Duplex):
Dimensional guide to be used only if upper bracket is
attached to cover as shown.
Thermal
Leak
Insulation
KW
Sensor
Sensor
1.5
No
No
1.5
No
No
1.5
No
No
1.5
No
No
1.5
Yes
Yes
1.5
Yes
Yes
1.5
Yes
Yes
1.5
Yes
Yes
2.2
Yes
Yes
2.2
Yes
Yes
3.0
Yes
Yes
3.0
Yes
Yes
5.6
Yes
Yes
2
Vert. Disch.
Pipe Length
Locking Rail Length
Guide
Rail
X
Y
Length
Z
2014 0995
SG12/SGC12
SG13/SGC13
X = 22-3/4" (58 cm)
Y =29-1/4" (74 cm)
Z = 19-3/8" (49 cm)
14" (36 cm)
24" (61 cm)
36" (91 cm)
SGC20
X = 25-7/16"(64.5cm)
Y = 26-3/4"(68 cm)
Z = 21-5/8"(55 cm)
16" (41 cm)
30" (76 cm)
42"(107 cm)
Winding Resistance in Ohms*
Class
B-W
B-R
B
.90
5.3
F
2.2/8.8
2.2/8.8
B
.90
5.3
F
2.2/8.8
2.2/8.8
B
.90
5.3
F
2.2/8.8
2.2/8.8
B
.90
5.3
F
2.2/8.8
2.2/8.8
B
.36
1.9
F
.74/2.96
.74/2.96
B
.36
1.9
F
.74/2.96
.74/2.96
F
.54/2.16
.54/2.16
R-W
6.2
2.2/8.8
6.2
2.2/8.8
6.2
2.2/8.8
6.2
2.2/8.8
2.26
.74/2.96
2.26
.74/2.96
.54/2.16

Publicité

loading