Télécharger Imprimer la page

FRANCO BELGE MONTFORT Notice De Référence page 24

Publicité

Les langues disponibles

Les langues disponibles

"MONTFORT" - ref. 134 05 01
3.8. Trouble Shooting
Problem
Fire difficult to start. Fire goes
out.
Fire burns too quickly
Smokes when lighting up
Smokes while burning.
Low heat output.
10
All manuals and user guides at all-guides.com
Probable causes
Wood green... or too damp
Logs are too big
Poor quality wood
Not enough primary air
Insufficient draught
Too much draught
Excessive draught
Poor quality wood
Flue duct is cold
Room is in decompression
(negative pressure)
Insufficient draught
Down draught
Room is in decompression
(negative pressure).
Poor quality wood.
Poor mixing of the convection air
þ : This sign means that you should
asked for a qualified engineer to do the
work.
-
Action
-
Use hard wood logs, which have been cut for at least
two years and stored, under a ventilated shelter.
-
To light the fire, use small, very dry twigs. To maintain
the fire, use split logs.
-
Use hardwood that have a higher calorific value per cu
metre (Yoke-elm, oak, ash, maple, birch, elm, beech,
etc.)
-
Open air control.
þ
-
Check that the flue is not obstructed, sweep it if
necessary
-
Seek advice from a chimney specialist.
-
Partially close the air control.
þ
-
Install a draught stabiliser to the connector pipe.
-
Do not continuously burn small wood, sticks, bundles,
carpentry offcuts (plywood, pallets), etc.
-
Burn paper and kindling wood to increase heat.
-
In houses equipped with mechanical ventilation, partly
open a window until the fire is well established.
þ
-
Vérifier la conformité du conduit de fumée et son
isolation.
-
Check that the flue is not obstructed, sweep it if
necessary
þ
-
Install an anti-down draught cowl.
þ
-
In houses equipped with mechanical ventilation, partly
open a window until the fire is well established.
-
Use hardwood that have a higher calorific value per cu
metre (Yoke-elm, oak, ash, maple, birch, elm, beech,
etc.)
-
Check the air flow system (air inlet, piping, air outlet).
-
Check that the next rooms are equiped with ventilation
grids to help out the hot air circulation.
Instructions for user