Safety Notes

Read and observe all instructions. The inte-
grated protections in the measuring tool may be
compromised if the measuring tool is not used
in accordance with the instructions provided.
SAVE THESE INSTRUCTIONS FOR FUTURE REF-
ERENCE.
 Have the measuring tool repaired only through qualified
specialists using original spare parts. This ensures that
the safety of the measuring tool is maintained.
 Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring tool
which may ignite the dust or fumes.

Product Description and Specifications

Working optimally with the measuring tool is
possible only when the operating manual and
working instructions are read completely,
and the instructions contained therein are
strictly followed. SAVE THESE INSTRUC-
TIONS.
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operat-
ing instructions.

Intended Use

The measuring tool is intended for quick and precise measur-
ing of inclines.

Product Features

The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1 Spirit level for horizontal alignment
2 Serial number
3 Battery lid
4 Latch of battery lid
5 Illuminated display
6 Spirit level for vertical alignment
7 Audio signal button
8 Button for changing the unit of measure
9 "ON/OFF" button
10 Button for calibration "Cal"
11 "Hold/Copy" button
12 Protective pouch
Display Elements
a Alignment aids
b/c Units of measure: °; %; mm/m
d "H" indicator for "HOLD" memory value
e Reading
f Battery indicator
g Indicator for audio signal

Technical Data

Digital level
Article number
Dimensions
– Length
– Width
– Height
Measuring range
Measuring accuracy
– 0°/90°
– 1°–89°
Operating temperature –10 °C ... +50 °C –10 °C ... +50 °C
Storage temperature
Batteries
Rechargeable
1)
batteries
1) Due to the lower voltage of the rechargeable batteries, the battery in-
dicator will not display a full charge.
The measuring tool can be clearly identified with the serial number 2 on
the type plate.
1 609 92A 25F | (25.2.16)
GIM 60
3 601 K76 700
3 601 K76 800
608 mm
27 mm
59 mm
0–360° (4 x 90°) 0–360° (4 x 90°)
±0.05°
±0.2°
–20 °C ... +70 °C –20 °C ... +70 °C
4x1.5V LR6(AA)
4x1.5V LR6(AA)
4x1.2V HR6(AA)
4x1.2V HR6(AA)
Bosch Power Tools
GIM 120
1250 mm
27 mm
59 mm
±0.05°
±0.2°