5. LOCATION AND CLEARANCE
5.1
CLEARANCE
IOM
IOM
The minimum clearances required for installation
and accessibility are shown below. These clearances
should be followed unless otherwise approved by the
manufacturer.
1
Unrestricted
Ensure the top discharge area is unrestricted for at
least 60" above the unit (Figure 1.).
Clearance must be provided in front of the access
panel for servicing and adequate airflow around the
cabinet as shown on Fig.1, 2 & 3.
The distance in between two or more units will be
24" minimum.
5.2
LOCATION RESTRICTIONS
Do not locate unit close to bedrooms or areas where
operational sounds may be objectionable (Fig. 4).
Outdoor unit location must be far enough away from
any structure to prevent excess runoff water from
pouring directly on to the unit (Fig. 5). Check with
National and Local Codes.
W415-2973 / B / 07.18.22
60"
Unrestricted
Service
Access
Panel
24"
12"
12"
Wall
ACCESS
ACCESS
Shrubs
PANEL
PANEL
24"
wall
12"
12"
12"
wall
2
12"
Service
Access
Panel
24"
12"
wall
3
MIN. 24" clearance
Min
for service
Service
from one side
Access
Panel
12"
12"
4
5
12"
12"