.Pressure lost or iron in
conditioned water.
.Loss of resin through
drain line.
.Control cycle
continuously.
1 .Drain flows
continuously.
11. alt water in soften
water.
12. nterupted or
irregular brine.
All manuals and user guides at all-guides.com
A. ron in the water supply pipe.
B. ron mass in the softener.
C. Fouled resin bed.
D. Too much iron in the raw
water.
A. Air in water system.
B. Bottom strainer broken.
C. mproperly si ed drain line
control.
A. Controller is faulty.
B. Time of regeneration steps
were set to ero
C. Locating signal wiring break
down
D. Foreign material stuck the
driving gear.
A. nternal valve leak.
B. When electricity fails to
supply valve stops backwash or
fast rinse position.
C. Control valve is in Backwash
status.
A. Foreign material in injector or
injector fails to work.
B. Brine valve cannot be shut off.
C. Time of rapid rinse too short.
A. Water pressure too low or not
stable.
B. njector is plugged or faulty.
C. Air in resin tank.
D. Floccules in resin tank during
backwash.
A. Clean the water supply pipe.
B. Clean valve and add resin cleaning chemical
increase fre uency of regeneration.
C. Check backwash brine draw and brine tank refill.
ncrease fre uency of regeneration and backwash
time.
D. ron removal e uipment is re uired to install
before softening.
A. Assure that well system has proper air eliminator
control.
B. Replace the bottom strainer.
C. Check for proper drain rate.
A. Replace the controller.
B. Check program setting and reset.
C. Check and connect locating signal wiring.
D. Take out foreign material.
A. Check and repair valve body or replace it.
B. Adjust valve to service position or turn off bypass
valve and restart when electricity supply.
A. Clean and repair injector.
B. Repair brine valve and clean it.
C. E tend rapid rinse time.
A. ncrease water pressure.
B. Clean or replace injector.
C. Check and find the reason.
D. Clean the floccules in resin tank.