Problem
1. oftener fails to
regenerate.
2. ncorrect
Regeneration Time
3. oftener supply hard
water.
4. oftener fails to draw
brine.
5. ystem uses too
much salt.
.E cessive water in
brine tank.
 
 

A ll manuals and user guides at all-guides.com
A. Control alve Fault
Cause
A. nterruption of electricity
B. Regeneration cycles set
incorrect.
C. Controller is defective.
D. Motor fails to work.
A. Time of Day is not set
correctly.
B. Power failure more than 3
days.
A. Bypass valve is open or
leaking.
B. No salt in brine tank.
C. njector plugged.
D. nsufficient water flowing into
brine tank.
E. Leak at
ring on riser pipe.
F. nternal valve leak.
G. Regeneration cycles not
correct.
H. hortage of resin.
. Bad uality of feed water or
turbine blocked.
. Adjusting bolt open
A. Line pressure is too low.
B. Brine line is plugged.
C. Brine line is leaking.
D. njector is plugged.
E. nternal control leak.
F. Drain line is plugged.
G. i es of injector and DLFC
does not match with tank.
A. mproper salt setting.
B. E cessive water in brine tank.
A. verlong refilling time.
B. Foreign material in brine line.
C. Foreign material in brine valve
and plug drain line flow control.
D. Not install safety brine valve
but power failure whiling salting.
E. afety brine valve breakdown.
COMAP GROUP - 16, avenue Paul Santy - BP 8211 - 69355 LYON Cedex 08 - FRANCE
Correction
A. Assure permanent electrical service Check fuse
plug pull chain or switch .
B. Reset regeneration cycles.
C. Replace controller.
D. Replace motor.
Check program and reset time of day.
A. Close or repair bypass valve.
B. Add salt to brine tank and maintain salt level
above water level.
C. Change or clean injector.
D. Check brine tank refill time.
E. Make sure riser pipe is not cracked. Check o ring
and tube pilot.
F. Change valve body.
G. et correct regeneration cycles in the program.
H. Add resin to mineral tank and check whether
resin leaks.
. Reduce the inlet turbidity clean or replace turbine.
. Close the adjustment bolt.
A. ncrease line pressure.
B. Clean brine line.
C. Replace brine line.
D. Clean or replace new parts.
E. Replace valve body.
F. Clean drain line flow control.
G. elect correct injector si e and DLFC according
to the After sales service re uirements.
A. Check salt usage and salt setting.
B. ee problem no. .
A. Reset correct refilling time.
B. Clean brine line.
C. Clean brine valve and brine line.
D. top water supplying and restart pr install safety
brine valve in salt tank.
E. Repair or replace safety brine valve.