CS450/750 series of electric strikes are designed for use with cylindrical and mortise locksets without deadbolt in hollow metal jambs.
The strikes can be configured to fail-safe or fail-secure on site (Non-Fire Rated).
12 VDC or 24 VDC
(Strike is polarity insensitive)
Humidity
0% to 85% Non-condensing
CS450
CS750
250,000 cycles
Control Device
All manuals and user guides at all-guides.com
Latch Monitor
(when applicable)
(as needed)
Red & Black: 12 VDC
White & Black: 24 VDC
(Non-polarized)
For details regarding the limited warranty:
Customer Service
1-877-671-7011
CS450
CS450-LBM
CS750
CS750-LBM
Destructive Attack: Level I
UL294
Performance Level
Line Security: Level I
UL Requirements
For indoor use only.
Wiring methods shall be in accordance with NFPA 70.
The CS450/750 Series is intended to be used with UL Listed Exit Hardware.
The CS450/750 Series shall not impair the intended operation of an emergency exit.
The CS450/750 Series shall not impair the operation of panic hardware mounted on
the door.
Overheated or burnt coils caused by incorrect voltage/wire
harness combinations will not be covered under warranty
Dual Voltage
Black
12 VDC
Red
White
Green
White
24 VDC
Green
Black
Red
(Polarity Free)
www.allegion.com/us
CS450/750 Series
Zinc Alloy for
Hollow Metal
Frame
Standby Power: Level I
Endurance: Level IV
CAUTION
47258559 Rev. 1/20-d
l
24 VDC
© Allegion 2020

Publicité

loading

Sommaire des Matières pour Allegion LOCKNETICS CS450 Serie

  • Page 1 Red & Black: 12 VDC Black 12 VDC White & Black: 24 VDC (Non-polarized) Control Device White Green White 24 VDC Green 24 VDC Black (Polarity Free) For details regarding the limited warranty: Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2020 47258559 Rev. 1/20-d...
  • Page 2 All manuals and user guides at all-guides.com Optional Lip Extension Brackets (sold separately) CSLE-2 CSLE-1 NOTICE Factory default setting is Fail-Secure. Insert Spring Screw Cap 1. Remove the screw cap, 2. Reverse the insert. 3. Replace the insert, spring take out spring and insert. and screw cap.
  • Page 3 24 V c.c. statut ouvert. Noir N.C. sortie de type contact sec : lorsque le microrupteur est Rouge activé par le pêne demi-tour. (non polarisé) Pour plus de détails concernant la garantie limitée : Service à la clientèle 1-877-671-7011 www.allegion.com/us...
  • Page 4 All manuals and user guides at all-guides.com Installation sur un cadre en bois ou en métal creux : Supports d’extension de rebord en option (vendus séparément) CSLE-1 CSLE-2 25 mm (1 po) 50 mm (2 po) Utilisation de la plaque de finition En cas de découpe excessive, utiliser la plaque de finition fournie pour masquer toute erreur.

Ce manuel est également adapté pour:

Locknetics cs750 serieLocknetics cs450-lbmLocknetics cs750-lbm