Instruction CF-RF Room Thermostat with Infrared Floor Sensor
Floor surface temperature limitation
. Ensure actual floor surface temperature is
shown in the display illustrated by
2. Press and hold the push button
MAX is also shown in the display
3. Press the up/down selector
maximum floor surface temperature limitation
4. Press the push button
also shown in the display
5. Press the up/down selector
mum floor surface temperature limitation
IMPORTANT!
As heat emission from the floor may vary slightly
depending on floor covering - and thereby cause
inaccurate temperature measurement - it may be
necessary to adjust the setting of max. and min.
floor surface temperatures accordingly.
! It is important always to follow recommendations
from the floor manufacturer regarding max. floor
surface temperature.
! It is recommended always to include mixing shunt
for floor heating circuits in order to ensure optimal
flow temperature. - In addition to minimised energy
consumption, correct setting of the flow tempera-
ture will eliminate the risk of excessive heat transfer
to the floor.
VI.UH.R2.1C
8
All manuals and user guides at all-guides.com
Produced by Danfoss Floor Heating Hydronics 03.2007
until SET
to set the
shortly, SET MIN is
to set the mini-