Instruction CF-RF Room Thermostat with Infrared Floor Sensor
4. Transmission Test
Initiate transmission test on Room Thermostat
- fig. 1
• Press the push button
• LED
goes ON
Link test is satisfactory
• LED
goes OFF
Link test is unsatisfactory
• LED
flashes 5 times
No link connection to Room Thermostat
• Try to relocate Room Thermostat in the room
• Or install Repeater Unit (CF-RU) and locate
between Master Controller and Room
Thermostat
Note: Master Controller output LED(s)
Room thermostat, flash(es) during link test
5. Mounting
Placing the Room Thermostat - fig. 3
• The Room Thermostat should be placed in
accordance with fig. 3
IMPORTANT!
Wherever possible, the room thermostat should
be installed at a place where the effect of sunlight,
VI.UH.R2.1C