Protection class
Permissible installation altitude above sea level, maximum
Conditions ambiantes - Valeur d'isolation
Rated insulation voltage U
i
Rated impulse withstand voltage U
Overvoltage category
Degree of pollution
Données électriques
Operating voltage
Operating current, minimum
No-load supply current I
, maximum
0
Rated operating voltage
Operating current
Required rated short-circuit current
Time to readiness, maximum
Switching frequency, maximum
Données électriques - Entrées de sécurité tout-ou-rien
Designation, Safety inputs
Current consumption of the safety inputs
Test pulse duration, maximum
Test pulse interval, minimum
Classification ZVEI CB24I, Sink
Classification ZVEI CB24I, Source
Données électriques - Sorties de sécurité
Designation, Safety outputs
Rated operating current (safety outputs)
Output current, (fail-safe output), maximum
Design of control elements
Voltage drop U
, maximum
d
imp
III
2 000 m
32 VDC
0,8 kV
III
3
24 VDC -15 % / +10 % (stabilised PELV power supply)
0,5 mA
35 mA
24 VDC
600 mA
100 A
2 000 ms
1 Hz
X1 and X2
5 mA
1 ms
100 ms
C1
C1
C2
C3
Y1 et Y2
250 mA
0,25 A
protégé contre les courts-circuits, commutation P
1 V
8-25