Télécharger Imprimer la page

Bosch W 325 K T1 Serie Manuel D'installation Et De Fonctionnement page 10

Publicité

Les langues disponibles

Les langues disponibles

PREVENTIVE MAINTENANCE
PILOT AND MIAN BURNER
Check pilot and main burners at least every 12 months for
proper flame characteristics.
The proper flame should envelop approximately 10 mm (3/8
inch) of tip of thermocouple.
Figure 11
If the pilot flame is too small, then the pilot burner must be
cleaned. The position of the igniter electrode should also
be checked to assure that electrode is approximately 3mm
(1/8") from pilot, see figure 11.
The main burner should exhibit the following characteristics:
- Provide complete combustion of gas.
- Cause rapid ignition and carryover of flame across burners.
- Operate quickly during ignition, burning, and extinction.
Figure 12
10
All manuals and user guides at all-guides.com
If the main burners fail to exhibit above characteristics they
must be cleaned, either by blowing them off with compressed
air or by washing them in soap and water and rinsing.
If it proves necessary to wash the main burner assembly
the following procedure should be used:
1- Turn off the gas supply to the water heater.
2- Disconnect pilot gas tube at the gas valve and unscrew
the gas manifold assembly union nut, where the gas
manifold inlet pipe connects to the gas valve and remove
the gas assembly.
3- Wash in soap and water and then rinse.
4- Reassemble – Check for gas leaks after reassembly
and correct as required.
5- Refer to Lighting Procedure to relight the heater.
VENTING
The vent piping and finned heat exchanger should be checked
at least once a year for dust and carbon deposits, and
cleaned as necessary.
PRESSURE RELIEF VALVE
At least once a year the pressure relief valve should be
checked to insure that if it is in operating condition. Before
testing the relief valve take necessary precautions to prevent
water damage. Lift the lever on the valve several times until
the valve seats properly and operates freely. Do not check
the relief valve when hot water is being drawn and the main
burner is on. Water exiting the valve under these conditions
would be hot.
If the pressure relief valve on the appliance discharges this
is an indication of water pressure above the pressure rating
of the relief valve. If the pressure relief valve continually
discharges on a periodic basis contact the water supplier or
local plumbing inspector on how to correct the situation. Do
not plug the pressure relief valve.
PERIODIC REMOVAL OF LIME DEPOSITS
After 12 to 24 months of service, depending on frequency
of use and water harness, the heater should be checked for
accumulation of calcium carbonate (lime) and delimed, if
necessary. Thereafter a regular schedule, based on initial
inspection findings, should be set up to delime the heater.

Publicité

loading

Ce manuel est également adapté pour:

W 400 k t2 serie