LCD DISPLAY (page 2)
1. Battery charge level.
2. Choice of battery type:
•
GEL: Lead-Calcium (PbCa), solid electrolyte, gel,
completely sealed battery. They are maintenance-
free batteries.
• AGM (ABSORBENT GLASS MAT): lead batteries
with electrolyte absorbed in fibreglass. Completely
sealed. They are maintenance-free batteries.
• AGM+: they ensure a higher number of start-ups
at higher current and more in-depth discharge than
standard AGM. Used on vehicles with Start-Stop
system. Compact dimensions, greater resistance to
vibrations and fast recharge times.
• Lithium (Li): batteries with reduced weight, high
energy density and very low auto-discharge. They
are mainly used in the world of motorsport.
• EFB (Enhanced Flooded Battery): liquid electrolyte
batteries with a higher recharge capacity and which
support a higher quantity of cycles (start-ups) than
traditional ones. Ideal for vehicles with Start-Stop
system.
If no type of battery is selected, the battery charger
automatically sets the type of battery.
3. Charges at low temperatures.
4. Battery voltage set.
5. RECOVERY mode.
6. Generic alarm for polarity reversal, short circuit,
worn or faulty battery.
7. SUPPLY mode.
8. PULSE-TRONIC charge phases.
9. BOOST mode.
10. TEST mode.
11. Alternator test and Starting Load Efficiency test
(CCA).
12. Outcome of TEST, RECOVERY and charge end.
13. FUNCTION - Setting button:
- PULSE-TRONIC CHARGE (GEL, AGM, AGM +, Li, EFB
and low temperatures
- TEST (battery status, battery starting load
efficiency, vehicle alternator).
- Advanced Programs: BOOST, RECOVERY, SUPPLY,
STARTER AID (
14. VOLT - Setting button:
- 12/24V battery voltage.
).
).
- 57 -
FUNCTIONS
A. PULSE-TRONIC CHARGE
B. TEST
- CHARGE STATUS TEST
- BATTERY CRANKING EFFICIENCY TEST (CCA)
- ALTERNATOR TEST
C. BATTERY MAINTENANCE
- RECOVERY
D. POWER SUPPLY
- SUPPLY
E. STARTER AID (if present)
OPTIONAL
INFO ALARM
CHARGER CABLES CONNECTION
SWITCH ON
230V - 1ph
50/60 Hz
SWITCH OFF
230V - 1ph
50/60 Hz
EN