Three-phase version:
Power supply 400...415V 3N
L1
L2
L3
Fig. 9
Open the power supply terminal board and insert the
jumpers provided as follows: one jumper between
terminals 2 and 4 and another between terminals 4 and
6. Using a suitable power supply cable (see technical
data table), connect the three phases to terminals 1, 3
and 5, the neutral to terminal 4 and the earth wire to the
terminal
.
Power supply 220...230V 3
L1
L2
L3
Fig. 10
Open the power supply terminal board and insert the
jumpers provided as follows: one jumper between
terminals 1 and 2, one between terminals 3 and 4 and
another between terminals 5 and 6. Using a suitable
power supply cable (see technical data table), connect
the three phases to terminals 1, 3 and 5 and the earth
wire to the terminal
.
Power supply 220...230V 1N
Fig. 11
Open the power supply terminal board and insert the
jumpers provided as follows: two jumpers between
terminals 1, 3, 5 and another two between terminals 2, 4
and 6.
Using a suitable power supply cable (see technical data
table), connect the phase and neutral to terminals 5 and
6 respectively and the earth wire to the terminal
8
All manuals and user guides at all-guides.com
Connections provided for energy control.
This appliance is designed for an external energy
consumption control.
Connect the energy peak controller across terminals 11
and 12.
Safety devices
•
•
•
•
Failure to comply with safety rules and regulations
relieves the manufacturer of all liability.
B3
If the appliance is connected to a water softener or
osmotic device, contact the detergent supplier for a
specific product.
Dishwashers with incorporated rinse-aid dia-
phragm dispenser pump (Fig. 13).
To change the dispensed amount, turn
accordingly (Fig. 13).
The diaphragm dispenser may be activated manually
by pressing screw "D" (Fig. 13).
.
11
12
Fig. 12
CAUTION
!
A normally open (n.o.) contact of the
controller must be connected across
terminals 11 and 12. When this contact
closes the boiler heating elements are
disconnected. Using the dishwasher in
these conditions may increase the cycle
time.
An automatic reset thermoamperometric protective
device incorporated in the windings of the electric
pump cuts off the electricity supply in the case of
malfunctioning.
In the event of water mains failure, a device
prevents water in the boiler from returning into the
mains.
An overflow pipe, connected to the drainage outlet,
maintains the water in the tank at a constant level.
On models with a drain pump, a supplementary
level control device activates if the main level
control device is faulty.
DETERGENT/RINSE-AID DISPENSERS AND
SETTINGS
on screw "D"