MT150PP, MT230PP, MT350PP, MT550PP
6.1 Connections and controls
No. in fig. 1,
page 3
1
2
3
4
5
6
7
8
9
10
11
6.2 LED indicators
LED
Batterie/n voll
> 80%
Laden
Standby
Schwach
(only MT 150 PP,
MT 230 PP)
AES/RE
(only MT 350 PP,
MT 550 PP)
EN
Description
Service connection (without function)
Remote display terminal
Solar panel terminals
House battery terminals
Starting battery (+) terminal
Temperature sensor terminals
AES/RE terminal
(only MT 350 PP / MT 550 PP)
EBL measurement output terminal
LED indicators
Fuse
DIP switches for setting battery type and AES/RE
Status
On
Lights dimly
Off
On
On
Flashing
Flashing once
Flashing
On
On
Off
Description
Batteries fully charged (100 %); U2 phase
Charging process in U1 phase
Charging process in I phase
High charge (80 – 100 %)
Charging current present, brightness indicates the intensity of
the charging current
Battery protection:
• High temperature protection (> 50° C)
• Low temperature protection (< –20/–30° C)
Solar input over voltage protection
Standby mode
Low voltage at the house battery
Excess solar power, "AES/RE" terminal is activated
No excess solar power, "AES/RE" terminal is inactive
Technical description