- Grasp the holder in one hand.
- With the other hand, take the first whisk and
insert the shaft A into the bore B of the whisk
holder drive shaft. Make sure the drive lugs D are
properly aligned with the notches.
- As you push the whisk into the holder drive shaft
C, rotate it slightly in order to slide the drive lugs
into the notches D of the drive shaft C, thereby
locking the whisk into place inside the shaft.
- To check that the whisk is properly fixed inside the
shaft C, gently pull the metal wires.
- Repeat this procedure with the second whisk. If
you cannot push it in properly, remove it, rotate it
90° and start again.
- Removing the whisk from the whisk holder
While griping the
ejector A in one
hand and the holder
B in the other, pull
the ejector in the
opposite direction of
the arrow.
- Removing the ejector
Hold the whisk by
the wires B in one
hand.
With the other hand,
pull the ejector A in
the direction of the
arrow (see figure).
W A R N I N G
• Always unplug the Immersion Blender
before cleaning it!
• Always dilute bleach according to the
instructions on the label
• Never run the motor assembly through a
dish machine.
• The type and concentration of the sanitation
agent must comply with 21 CFR 178.1010
regulations.
• Clean according to local health department
regulations.
• MOTOR HOUSING
The Immersion Blender must be clean through
all stages of production. Clean between each
job using a detergent or disinfectant. Dilute the
detergent / disinfectant following the instructions
normally specified on it's packaging container.
Use a cloth lightly dampened (not dripping)
with the cleaning solution. Do not allow liquid to
come into contact with the electrical components
contained within the housing. Be careful when
cleaning around vents do not allow liquid to
drip or seep into the housing. Use a cloth lightly
dampened (not dripping) with water to remove
detergent / disinfectant then dry using a clean
cloth.
After using the Immersion Blender in a hot mixture,
cool the bottom of the tube in cold water before
disassembling the bell from the tube.
Clean immediately after use to prevent product from
sticking to surfaces.
CLEANING
Never immerse motor housing and/or handle
in liquid! The housing contains the electrical
components and is not sealed against liquid.
Contact with liquid can cause damage to the
blender and serious injury to the operator.
• FOOT AND BELL
It is possible to proceed in two ways:
AFTER EACH USE
1) Fill an appropriate container with hot water at
60 to 70°C and add dishwashing liquid.
Turn on the mixer for 20 seconds.
2) Unplug the mixer.
3) Using a brush, clean the outside of the tube and
bell with hot water and, if necessary, with the
detergent used above.
4) Rinse in warm water. Plug in the mixer again
and turn on for another 10 to 15 seconds.
AT THE END OF THE DAY
5) After disconnecting the mixer, detach the bell
from the foot to remove any condensation.
6) Carefully dismount the different parts of the bell
using the tool provided taking care not to da-
mage the blade shaft surfaces and cartridge gas-
kets. Clean each part using a mild detergent. The
blades are sharp and must be handled with care.
7) Immerse the foot, detached from the bell, in a
mild detergent solution for one minute. Rinse and
let dry before re-attaching the bell.
8) After cleaning, dry all the parts carefully to
prevent oxidation.