CE tested machines meet all valid EC machine guidelines as
well as all relevent guidelines for each machine.
1.
The machine has been built in accordance with state-of the-art
standards and the recognized safety rules. Nevertheless, its
use may constitute a risk to life and limb of the user or of third
parties, or cause damage to the machine and to other material
property.
2.
The Kity circular saw bench is constructed exclusively for the
sawing of wood. The required saw blade should be inserted
according to the cut type and the wood type (solid wood, chip
board or plywood).
3.
The machine must only be used in technically perfect condition
in accordance with its designated use and the instructions set
out in the operating manual, and only by safety-conscious per-
sons who are fully aware of the risks involved in operating the
machine. Any functional disorders, especially those affecting
the safety of the machine, should terefore be rectified immedia-
tely.
4.
When used in enclosed rooms, the machine must be connected
to a vacuum exhaust unit. Use the vacuum exhaust unit ha
3200 or ha 2600 to remove matchwood or saw dust. The vacu-
um support flow rate must be 20 m/s. Subatmospheric pressure
1200 Pa.
The Kity automatic switching unit is available as a special
5.
accessory. The vacuum exhaust unit automatically switches on
after a 2-3 second delay after the machine tool is turned on.
The machine has been built using modem technology in accordance
with recognized safety rules. Some remaining hazards, however,
may still exist.
D GB
•
The rotating saw blade can cause injuries to fingers and hands
if the work piece is incorrectly fed.
•
Thrown work pieces can lead to injury if the work piece is not
properly secured or fed, such as working without a limit stop.
•
Noise can be a health hazard. The permitted noise level is
exceeded when working. Be sure to wear personal protective
gear such as ear protection.
•
Defective saw blades can cause injuries. Regularly inspect the
Scope of delivery
Technical Data
Overall length with table extension mm
Overall length without table extension mm
Overall width mm
Overall height mm
Table size mm
All manuals and user guides at all-guides.com
Use only as authorized m
6.
7.
8.
9.
10. The Kity Table Circular Saw may only be used, maintained,
11. The Kity Table Circular Saw may only be used with original
Remaining hazards m
•
•
•
•
415
18
This avoids overloading the circuit fuse. After turning off the ma-
chine tool, the vacuum exhaust unit remains on for an additio-
nal 3-4 seconds and is then automatically switched off. Remai-
ning dust is thereby removed by vacuum exhaust, as required
by German regulations governing hazardous materials. This
results in savings in electricity consumption and reduces noise
levels, as the vacuum exhaust unit is on only during machine
tool operation.
For work in commercial spaces, the Kity dust remover woova
7 must be used. Do not remove or shut off vacuum exhaust
systems or dust removers while machine tools are operating.
Any other use exceeds authorization. The manufacturer is not
responsible for any damages resulting from unauthorized use;
risk is the sole responsibility of the operator.
The safety, work and maintenance instructions of the manufac-
turer as well as the technical data given in the calibrations and
dimensions must be adhered to.
Relevant accident prevention regulations and other, generally
recognized safety-technical rules must also be adhered to.
and operated by persons familiar with and instructed in its
operation and procedures. Arbitrary alterations to the machine
release the manufacturer from all responsibility for any resulting
damages.
accessories and saw blades from the manufacturer.
structural integrity of saw blades.
The use of incorrect or damaged mains cables can lead to
injuries caused by electricity.
The operating instructions supplied with the special accessories
must be observed and carefully read when Kity special acces-
sories are used.
Even when all safety measures are taken, some remaining
hazards which are not yet evident may still be present.
Remaining hazards can be minimized by following the instruc-
tions in „Safety Precautions", „Proper Use" and in the entire
operating manual.
Circular saw bench with motor and switch
Feet and cross - struts
Saw blade Ø 315 mm
Dust bag connector
Covering cape
Suction tube NW 50 x 2 m
Riving knife
Longitudinal stop with angle bar
Table extension
Cross cutting jig
Saw blade key
Push stick
Operating instruction
1265
850
690
1095
790 x590