‐ Flowmeter
Used to verify the correct functioning of the ventilation unit.
‐ Battery charger
Tab.1 ‐ LIST OF DEVICES WITH TURBINE 170
Name
TURBINE CFU SET
TURBINE FU SET
TURBINE H SET
TURBINE TM 1708 SET
TURBINE TM 1708 S SET
TURBINE TM 1708 G SET
TURBINE TM 1708 SG SET
TURBINE TM 1708 TP SET
TURBINE TM 1702 2 SET
TURBINE TM 1702 3 SET
TURBINE TM 1702 S3 SET
The devices with TURBINE 170 are designed and certified to function with the following SPASCIANI filter models:
‐ 100 P3 R (cod. 124150000) – anti‐dust filter, with P R SL protection according to EN 12941 and EN 12942
‐ 202 A2B2E2P3 R D (cod. 123350000) – combined filter, with A1B2E2 P R SL protection according to EN 12941 and EN 12942
‐ 202 A2B2P3 R D (cod. 123320000) – combined filter, with A1B2 P R SL protection according to EN 12941 and EN 12942
The filters are equipped with a normalised threaded connection EN 148‐1 and have to be connected, as a couple, to the
two attachments for filters which can be found on the ventilation unit.
For the performance provided by the ventilation filters with different types of filters see tab. 2.
ATTENTION: The marking according to EN 12941 and EN 12942 in Example C at the end of this information leaflet should
not be confused with markings that are related to other applicable standards (e.g.: EN 143 and EN 14387). For further
information please consult the instructions enclosed with the filters.
Tab.2 – Classes and levels of protection for the filtration fan + filters
Protection
Standard
Class
TH2
EN
12941:1998+
TH2
A2:2008
TH2
TM3
EN
12942:1998+
TM3
A2:2008
TM3
3. WARNINGS/LIMITATIONS
-
The filtering fans with masks/helmets/hoods should not be used for emergency situations or in environments where
the concentration of pollutants poses an immediate danger for the operator's life. For the maximum concentrations
of use, please refer to the table annexed to the filters' instructions, and in any case one should never exceed
concentrations of 400 times the TLV (for definitions please refer to European standard EN 529).
-
The apparatus is designed in such a way that it can be used during the decontamination shower, however during
decontamination it has to be worn and functioning.
-
Do not use the devices in atmospheres with an oxygen content which is inferior to 17% in volume, or even in closed
environments such as tanks, pipes, canals, etc.
-
Do not use the apparatus in environments with high explosion risk.
-
In case of heavy work, during respiration a negative pressure may build up in the hood reducing the protection factor.
-
Never change or modify the devices, as this may result in a reduction of the protection provided to the user.
-
WARNING: The apparatus is designed to provide adequate protection only when it is switched on. If the apparatus is
switched off, this may result in an increase of CO
will enable the operator to breathe filtered air through the tube, therefore this set‐up is more adequate for
interventions in high risk zones. The interruption of the ventilator, however, is an anomalous situation, and the user
should immediately leave the work area should this happen.
Code
Hood/helmet/mask
130860000
CFU Helmet with visor (133500100)
130870000
FU Light visor (133510100)
130880000
H Tyvek® Hood F (133520100)
130830000
TR 82 (112190000)
13083000S
TR 82 S (112170000)
130840000
TR 82 vetro sicurezza (112220000)
13084000S
TR 82 S vetro sicurezza (112250000)
130850000
TR 82 schermo antisfriso (112240000)
130810000
TR 2002 CL2 (113020000)
130820000
TR 2002 CL3 (113030000)
13082000S
TR 2002 S CL3 (113080000)
Filter model
100 P3 R
202 A2B2E2P3 R D
202 A2B2P3 R D
100 P3 R
202 A2B2E2P3 R D
202 A2B2P3 R D
and a decrease in O
2
Filter protection
level (EN 12941 –
CFU FU
EN 12942)
P R SL
x
A1B2E2 P R SL
x
A1B2 P R SL
x
P R SL
A1B2E2 P R SL
A1B2 P R SL
. Wearing the mask in an emergency situation
2
Breathing hose
TUR 802 (118420000)
TUR 802 (118420000)
TUR 802 (118420000)
TUR 803 (118430000)
TUR 803 (118430000)
TUR 803 (118430000)
TUR 803 (118430000)
TUR 803 (118430000)
TUR 803 (118430000)
TUR 803 (118430000)
TUR 803 (118430000)
TURBINE SET
TM
TM
H
1708
1702
x
x
x
x
x
x
x
x
x
x
x
x