Télécharger Imprimer la page

Spasciani TURBINE 170 Manuel D'utilisation page 6

Publicité

Les langues disponibles

Les langues disponibles

WARNING 
Only  strict  observance  of  the  rules  contained  in  this  manual  can  guarantee  proper  functioning  and  a  safe  use  of  the 
TURBINE 170 filter fans. SPASCIANI S.p.A. does not assume any responsibility for any damage that may occur following the 
incorrect or inappropriate use of the TURBINE 170 filter fans, nor for maintenance or repair operations that are not carried 
out within the company's premises or by other organisations as expressly approved by the company itself. Please note that 
the  breathing  protection  apparatus  should  be  used  by  specially  trained  personnel  and  under  the  supervision  and 
responsibility of persons who are perfectly aware of the limits of application and of the legislation in force. 
The use of non‐original accessories or parts is prohibited and will void the warranty for the breathing apparatus. 
 
1. INTRODUCTION 
The TURBINE 170 is a filtering device that protects the respiratory tract. The ventilation unit which is carried on the belt 
takes in air through a filter and expels it (filtered) through a pipe into a hood, a helmet or a mask. The flow of filtered air 
creates a positive pressure inside the hood/helmet/mask and impedes the entry of external contaminated air into the 
operator's  breathing  area.  The  continuous  flow  of  air  facilitates  breathing  and  impedes  the  visor  from  steaming  up, 
therefore ensuring maximum comfort for the operator. In order to obtain maximum protection it is necessary to choose 
the correct combination of the TURBINE 170 ventilation set, with filter, hood, helmet or mask.  
Please  consult  the  following  tables  for  the  possible  combinations  of  hood/helmet/mask  and  for  the  protection  levels 
offered by various filters. 
 
2. DESCRIPTION / SCOPE OF APPLICATION 
The TURBINE 170 is made up of the following components: 
 
‐ TURBINE 170 ventilation unit  
Made up of a plastic container which contains a fan, an electric motor and a battery pack. At the bottom of the unit there 
are two air inlets, threaded to secure the filters. A cylinder at the top allows air to escape; it is threaded internally to secure 
the breathing tube. There are two lateral loops for connection of the back brace. At the top there is a power switch and 4 
LEDs which indicate the status of the battery and flow.  
 
‐ Belt with renal cushion  
The belt, in extinguishing tape with nylon clasps, passes through the two rings which can be found on the body of the 
ventilation  unit.  This  has  a  renal  cushion,  so  that  the  device  can  be  worn  in  a  more  secure  and  comfortable  way. 
Alternatively it can be supplied a transparent PVC belt. 
The TURBINE 170 is the main component in a series of devices, described in table 1. 
The other components of the device are: 
 
‐ Breathing hose 
Made of polyurethane and internally reinforced with a plastic spring, equipped with a male connector which is threaded 
so that it may be connected to the ventilation unit, and a bayonet connector for the connection to the helmet/hood or a 
fitting connector for connection to the full mask.  
 
‐ Protection systems for the face/head: hood/helmet/mask 
The TURBINE 170 has been approved in combination with the helmet, the hood with visor, the light Tyvek® hood with 
visor,  and  with  the  masks  listed  in  the  following  table,  according  to  the  Standards  EN  12941:1998+A2:2008  and  EN 
12942:1998+A2:2008 as PPE (personal protective equipment) which protect the respiratory tract according to Regulation 
(EU) 2016/425. 
 
 
 
CFU 
Helmet with visor 
 
Level of 
TH2 
protection 
EN 12941:1998 
Standard 
+A2:2008
                       
   
EN    USER MANUAL 
Models hood/helmet/mask
FU
Light visor
Tyvek®F Hood
 
 
TH2 
EN 12941:1998
EN 12941:1998
+A2:2008
 
 
H
TR 82 
 
TH2 
TM3 
EN 12942:1998 
+A2:2008
+A2:2008 
TR 2002 
 
 
TM3 
EN 12942:1998
+A2:2008
6 / 20 

Publicité

loading