OPERATION
• Use this product only when you have carefully read the assembly and operating
manual.
• For your own safety, observe all the safety messages in this assembly and
operating manual.
• Please also consider the safety of others.
If the excess flow device SBS has been triggered, the valve (in the supply line, on the gas
cylinder, or on the pressure regulator) must be closed. The valve may only be re-opened once
the reason for the excess flow device SBS being triggered has been eliminated.
The valve must always be in the completely "open" position if the valve disposes of setting
options between completely "open" and completely "closed".
This is to ensure that the excess flow device SBS works properly.
TROUBLESHOOTING
Fault cause
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
Hose line is defective
Excess flow device SBS
Medium pressure does not
respond
No gas at the consumer
RESTORATION
If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.
REPLACEMENT
If there is any sign of wear or if the product or parts thereof are damaged, it must be replaced.
When the product has been replaced, observe the steps ASSEMBLY, LEAK TESTING and
START-UP.
MAINTENANCE
Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.
SHUT-DOWN
Close the gas supply and then the shut-off fittings of the connected loads. When the LPG
system is not in use, all valves must remain closed.
Action
Close the gas supply.
Do not use any electric switches.
Do not use a phone in the building.
Ventilate rooms well.
Shut down the LPG system.
Contact a specialised company.
Immediately close the gas cylinder valve.
Replace the hose line.
Check length and nominal internal diameter of the hose
line pursuant to Tables 1-3.
Press the control knob of the excess flow device SBS
(see STARTUP).
Check all connections of the supply line downstream of
the SBS for leak-tightness.
Check the level of the gas cylinder.
Excess flow device SBS
9 / 10