Risk of asphyxiation from gas leaks in enclosed spaces!
High concentrations of gas can cause difficulty in breathing and lead to unconsciousness.
Please provide for sufficient ventilation during indoor use.
INTENDED USE
Operating media
• LPG
You will find a list of operating media with descriptions, the
relevant standards and the country in which they are used in the Internet at
www.gok-online.de/de/downloads/technische-dokumentation.
Place of operation
• May be used indoors and outdoors
Risk of asphyxiation from gas leaks in enclosed spaces!
High concentrations of gas can cause difficulty in breathing and lead to unconsciousness.
Please provide for sufficient ventilation during indoor use.
Installation location excess flow device SBS: Application examples
Excess flow device SBS
Low pressure
• connection to the outlet of
the low pressure regulator
• protection of hose lines
Medium pressure
• connection to the outlet of
the medium pressure
regulator
• protection of hose lines
High pressure
• direct connection to gas
cylinders
• protection of high-pressure
hose lines in multiple bottle
arrays
3 / 10