Further Details - Advanced Menu - MISTER MENUISERIE motorisationplus-RUN24 Instructions D'installation Et Guide De L'usager

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
SBS
8
DLY
9
LSI
10
BlT
11
SBY
12
nMt
13

6 - FURTHER DETAILS - ADVANCED MENU

The Advanced menu allows the system to be further customised
by modifying parameters not accessible from the basic menu.
To access the ADVANCED menu, press the MENU button and
hold it down for 5 seconds.
PARAMETERS
SP.h.
1
Ph.2.
2
tP.h.
3
Ed.m.
4
iE.D.
5
tE.D.
6
LP.o.
7
TP.C.
8
FP.r.
9
tP.r.
10
40
STEP BY STEP or SBS configuration:
0 = Normal (AP-ST-CH-ST-AP-ST...)
1 = Alternate STOP (AP-ST-CH-AP-ST-CH...)
2 = Alternate (AP-CH-AP-CH...)
3 = Apartment block – timer (N.B TCL ≠ 0)
4 = Apartment block with immediate reclosure
Second leaf delay on opening
Deceleration distance
0 to 100 = Motor deceleration percentage during
opening and closure
Post blackout procedure
0 = No action, remains stationery
1 = Closure
Energy saving: enables photocell switch-off when
gate
is closed
0= disabled
1= enabled
Number of motors
1 = 1 motor
2 = 2 motors
DESCRIPTION
Use of PHOTO1 when starting from closed
0 = PHOTO1 is checked
1 = The gate starts even with PHOTO1 excited
Use of PHOTO2
0 = Enabled during both opening and closing AP/CH
1 =Only enabled during opening AP
Photo-device test
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
STOP/EDGE input selection
0 = STOP contact (NC)
1 = Resistive safety edge (8k2)
2 = Contact safety edge (NC)
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
Edge test
0 = off
1 = on
Partial opening
Time for automatic closure from partial opening
(0=off)
Flashing light output setup
0 = Steady
1 = Flashing
Pre-flashing time (0 = off)
0
2
20
0
0
2
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU.
N.B. Some default functions/display items may vary with respect to
the type of motor selected.
DEFAULT
1
0
0
0
0
0
50
0
1
0
0
4
0
300
0
100
%
0
1
s
0
1
1
2
MIN
MAX
UNIT
0
1
0
1
0
3
0
2
0
1
0
1
0
100
%
0
900
s
0
1
0
20
s

Publicité