4.2 - Display during normal operation
In "NORMAL OPERATING MODE", i.e. when the system is powered up normally, the 3-figure LCD display shows the following status messages:
MESSAGES MEANING
Gate closed or switch-on after shutdown
--
OP
Gate opening
CL
Gate closing
Gate stopped during opening
SO
Gate stopped during closure
SC
F1
Photocell 1 tripped
Photocell 2 tripped
F2
Gate stopped by external event
HA
ALI
Re-alignment procedure
Gate stopped without automatic reclosure
oP
Gate in partial opening mode
OPd
Pe
Gate in partial opening position without automatic reclosure
Gate open with timed reclosure - Flashing dash counting in progress
-tC
Dash replaced by figures 0..9 countdown (last 10s)
Gate in partial opening position with timed reclosure - Flashing dash counting in progress
-tP
Dash replaced by figures 0..9 countdown (last 10s)
L--
Learning stopped due to activation of safety device or motor inversion
Learning on M1 opening
LOP
Learning on M2 opening
LO
.
P
.
LCL
Learning on M1 closing
Learning on M2 closing
LC
.
L
.
Point of M1 deceleration on opening (only during stroke learning)
SOP
SO
P
Point of M2 deceleration on opening (only during stroke learning)
.
.
Point of M1 deceleration on closing (only during stroke learning)
SCL
Point of M2 deceleration on closing (only during stroke learning)
SC
.
L
.
EVENT
DESCRIPTION
opening
Gate opening
closure
Gate closing
automatic closure
Gate open with timed reclosure active
stop during closure
Gate stopped during closure
stop during opening Gate stopped during opening
open
Gate completely open without automatic reclosure
closed
Gate completely closed
programmation
During the programming phase
obstacle M1/M2
Motor 1/2 obstacle detected
photo 1!
Photocell 1 tripped
photo 2!
Photocell 2 tripped
sensitive edge!
Sensitive edge tripped
partial opening
Partial opening in progress
automatic partial
Gate opening to partial position with timed reclosure activated
closure
realignment
Realignment after a manual release
phototest error
Phototest error detected
IND/ELEC error
Electric lock / gate open light line overload
Malfunctions
This section lists a number of malfunctions which may occur.
SURGE OVERLOAD ALARM
EOL
EO.L.
SAFETY EDGE ALARM
EED
PHOTOCELL ALARM/SAFETY EDGE
EPH
The motor's current drawdown has increased very quickly
1. The gate has hit an obstacle (M1)
2. There is friction on the leaf of M1
1. The gate has hit an obstacle (M2)
2. There is friction on the leaf of M2
The control unit has received a signal from the safety edge
1. The safety edge has been pressed.
2. The safety edge is not connected correctly
Phototest fail outcome
1. Check the photocell and the safety edge connections
2. Check that the photocells and the safety edg are operating correctly
FLASHING INDICATION AND
CONTROL UNIT KEY LED
2 quick flashes + pause + 1 flash
4 quick flashes + pause, 3 times
2 quick flashes + pause, 3 times
2 quick flashes + pause, 3 times
5 quick flashes + pause, 3 times
3 quick flashes + pause, 3 times
6 quick flashes + pause, 3 times
EN