How to set regulator
1. Close the Shut Off Valve on the Regulator,
and open the CO
turning it counterclockwise.
2. Slowly turn Pressure Dial all the way to the
negative ( - ), then pull the Pressure Relief
Valve (PRV) to ensure an accurate reading.
Then very slowly turn the Pressure Dial
clockwise until the desired pressure is shown
on the Output Pressure Gauge (8-12 psi is
recommended).
• Turning clockwise will increase the output
pressure (higher psi).
• Turning counter-clockwise will decrease the
output pressure (lower psi).
3. Once desired pressure is reached, tighten the
inner Locking Ring. Pull the PRV to assure the
correct setting. If necessary, readjust your
settings. Next, open the CO
on the Regulator to allow gas to flow from
the Regulator to the Keg Coupler. You will
hear the keg pressurizing. The output needle
will drop momentarily until the pressure has
equalized. Then the needle will return to the
point you set it at.
4. Finally, we suggest you re-check the output
pressure on the Regulator, and if necessary
re-adjust starting at step #1 until the desired
pressure is reached.
Tank valve completely by
2
Shut Off Valve
2