Electrical Requirements - Haier HCC2220BEB Instructions D'installation

Masquer les pouces Voir aussi pour HCC2220BEB:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description
(J)
Width of cooktop opening
(K)
Min. clearance from edge of opening to nearest
side wall
(L)
Min. clearance between back wall and cooktop
a
24" (61 cm) min. clearance if bottom of wood or metal cabinets is protected by not less than ¹⁄₄"
(0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015" (0.04 mm)
stainless steel, or 0.024" (0.06 cm) aluminum or 0.020" (0.05 cm) copper.

ELECTRICAL REQUIREMENTS

Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to do so can result in death, fire or electrical shock.
If codes permit, and a separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path is adequate and wire
gauge is in accordance with local codes.
Check with a qualified electrical installer if you are not sure the cooktop is properly
grounded.
Do not use an extension cord.
In U.S.A. :
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/ NFPA No. 70-latest edition
and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
In Canada:
Be sure that the electrical connection and wire size are adequate and in
conformance with CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
WARNING
Electrical Shock Hazard
5
Dimension
22⁵⁄₈" (57.5 cm)
2" (5.08 cm)
1" (2.5 cm)