TYPICAL INSTALLATION
Pos.
Description
A
Air shut-off valve
B
Filter/ Regulator
C
Air hose
D
Quick coupling
E
Air nipple
F
1:1 Pump PM2 (200 l drum)
G
Oil hose
H
High delivery control valve
REPAIR AND CLEANING PROCEDURE
WARNING: Before starting any kind of maintenance or repair,
!
disconnect the compressed air supply and open a downstream
valve to relieve the oil pressure.
AIR MOTOR (Fig. 4)
• Unscrew the suction tube. Be careful not to damage O-ring (E).
• Remove pin (A) to separate the lower part of the pump.
• Remove screws (D) and pull the air motor dolly to remove it. The air
• motor parts will be accessible.
• Replace parts (B) and (C) if required.
• Clean of replace any damaged part.
INVERTER SET (Fig. 5)
Follow the procedures described in the "Air motor" procedure.
• Pull the air valve assembly (A).
CAUTION: The air valve assembly is assembled in a certain position.
Please check the correct position when re-assembling the pump.
• Attach the shaft (H) to a rubber-covered-clamp vice.
• Take out the air pass cap (B) with an Allen key.
CAUTION: The thread has non-permanent sealant that has to be
applied again when re-assembling the pump.
• Be careful not to damage the O-Ring (C) in the air pass cap (B).
• Parts (D, E, F, G) are ready to be replaced and/or cleaned.
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
A
B
C
D
Part No.
950319
240500
246010
253114
259014
352120
362303
361000
A
B
C
C
B
B
D
E
G
F
E
A
B
C
D
E
F
G
H
Fig. 4
EN
H
Fig. 3
Fig. 5
3
R. 02/23 835 806

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

351120352120356120

Table des Matières