TECHNICAL INFORMATION:

Composition (Fig. A)
1.
handle
2.
screw
3.
sliding disc
4.
teflon ring
5.
rod cap
6.
tap body
7.
aerator
8.
vertical rod
9.
O-ring
10. ring nut
11. O-ring
Supply
Hot water temperature
Working pressure
If working pressure is over 5 BAR, we recommend using a pressure reducer. This tap
is not compatible with the use of low-pressure instantaneous hot water heaters.
TIPS ON INSTALLATION:
Important: the hot water must be connected to the left pipe, the cold water to
the right pipe.

INSTALLATION:

After shutting off the mains, disassemble the old tap.
Clean the threads of the mains very well.
Instructions for correct installation:
Fig. C
Insert O-ring -20- in its housing on the tap body.
Fig. D
Place the stud bolt -21- and the flange -23- on the shaped seal -22- then tighten the
tap with the stay -24-.
Fig. E
To mount the drain, insert the tapered seal -31- onto the drain -32- and insert the
drain into fixture. Position the seal -30- into its housing on the drain body -29 and
screw the drain body until it is firmly in place (if necessary, use silicone between the
ceramic and the drain -32-).
Fig. F
Insert the vertical control rod -26- into the designated hole on the tap. Connect the rod
to the horizontal rod -28- using the clamp -27- and adjust the travel of the cap -33-.
12. cartridge
13. bushes
14. springs
15. O-ring
16. O-ring
17. O-ring
18. O-ring
19. internal body
20. seal
21. stud bolt
22. seal
Recommended
65°
3 BAR
13
23. flange
24. stay
25. supply tubes
26. clamp
27. horizontal rod
28. drain body
29. seal
30. tapered seal
31. drain
32. cap
33. stand
Maximum
80°
5 BAR
Minimum
15°
0.5 BAR