Télécharger Imprimer la page

Cooper Lighting Solutions Portfolio LAM4B Multi Head Instructions D'installation page 4

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions – LAM4B Multi Head Installation
i. Draw Input wires (Black, White & Green) from
flexible conduit through access plate.
ii. Connect Black to Black and White to White wires by
using wire nuts provided. (Figure 1.6)
iii. Connect Ground wire to driver back plate using
#8-32 screws
White Wire
Figure 1.6.
iv. Assemble access plate with #8-32 screws back to
housing by tucking wires inside, Connect flexible
conduit to access plate. (Figure 1.7)
Figure 1.7.
4
Cooper Lighting Solutions
Black Wire
Wire nuts
Access Plate
#8-32 Screw
Flexible
Conduit
Ground Wire
Flexible conduit
IB520102ML
Installation instructions
4.
Once the connections are done, Install the fixture plate
with light into the housing. Ensure wires do not get
pinched along the edges of plate. Install #8-32 screws.
(Figure 1.8.)
Figure 1.8.
5.
Different multi-head units will have different cut-out
sizes
(Refer to ceiling cut-out sizes below).
• 1 Light: 5 9/16" X 6 1/16" (Figure 1.9)
• 2 Light: 10 13/16" X 6 1/16" (Figure 1.10)
• 3 Light: 16 1/16" X 6 1/16" (Figure 1.11)
• 4 Light: 21 5/16" X 6 1/16" (Figure 1.12)
5 9/16"
6 1/16"
Figure 1.9.
Figure 1.10.
Figure 1.11.
Figure 1.12.
T-Grid
10 13/16"
6 1/16"
16 1/16"
6 1/16"
6 1/16"
21 5/16"

Publicité

loading