12.5 FAQs

QUESTION
Is it possible to connect two
heating circuits to one Unibox
RTL?
How many m² of temperature
regulation surface can be con-
nected to the Unibox RTL?
Can the Unibox RTL be oper-
ated with an actuator?
Can the Unibox RTL be oper-
ated with a remote control?
40
RESPONSE
Yes, use a Duo connection piece to connect two heating cir-
cuits of the same length to one Unibox RTL. Each surface tem-
perature regulation circuit may have a maximum pipe length of
80 m, provided you use 16/17 mm pipes.
Illust. 23: Connection scheme of two heating circuits with Duo
connection piece
You can connect a surface covering approximately 20 m² per
Unibox RTL. The pipe length must not exceed 100 m when
using a 17 mm pipe.
No, actuators are suitable for Uniboxes with individual room
temperature control only.
No. remote controls are suitable for Uniboxes with individual
room temperature control only.