Thermador Masterpiece HMWB30WS Instructions D'installation page 9

Masquer les pouces Voir aussi pour Masterpiece HMWB30WS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Considerations
Clearances and requirements
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the applian
ce's installation manual.
4
5
/
"
16
(110)
11"
(280)
30" (762) min over a gas cooktop
30" (762) min over an electric cooktop
NOTICE: The hood could incur some damage from heat
if a THERMADOR MASTERPIECE ® series cooktop is opera -
ted with multiple burners at high settings under a hood that
is installed at minimum clearances.
Unit Weight
-
This vent hood is heavy. Adequate structure and support
must be provided in all types of installations.
When calculating the load for the housing support
system, be sure to consider the weight of the
ventilation unit.
Unit
30'' (76 cm)
IMPORTANT:
The supplied weights address only the ventilation unit and
blower. Installer must account for weight of any materials
of construction when calculating the total dead weight
load of installation, including but not limited to: wall, tile,
mortar, plaster, brick, inishes, partitions, and other similar
additional requirements and/or standards apply to speciic
Weight