Common Ducting Conigurations
RECIRCULATING MODE
C
E
F
NOTE: The igure does not represent all conigurations or installation methods. The image is to be used as a guide ONLY.
NOTE: Flexible duct is not recommended. Flexible
ductwork creates back pressure and air turbulence that
greatly reduce performance.
Vent system can terminate either through the roof or wall.
Always install a metal vent cover where the ductwork exits
the house.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to
the outside, models HMWB30WS and HMWB36WS can
be used in the non-vented (recirculating) version, using the
recirculating kit (sold separately). Fumes and vapors are
recycled through the grid.
See optional accessories section.
VENTING THROUGH THE WALL
D
A
B
F
VENTING THROUGH THE CEILING
C
B
A
F
Hood Transition
Vertical Discharge Transition
The hood is shipped ready for vertic
The transition supplied with the hoo
10" round duct. The igure shows the transition connected
6"
CL
(152.5)
4
/
"
5
16
(110)
11"
(280)
A. 10" round transition
B. 10" round duct system
C. Cabinet / Duct cover kit
D. 90° elbow
E. Recirculating kit
F. Installation height:
Gas range MIN: 30" (76.2 cm)
Electric range MIN: 30" (76.2 cm)