Before drilling the second mounting hole,
re-level the mount.
Avant de percer le deuxième trou de mon-
tage, rééquilibrer le support.
Step 7. Drill a pilot hole at the marked location using a
power drill and a 1/4" drill bit.
Step 8. Align the mounting slot with the drilled hole.
Step 9. Insert and tighten one (1) 5/16" x 3" lag bolt and
flat washer. Tighten using a 1/2" socket
wrench. Do not completely tighten the lag bolt
at this time.
If the studs are 12" (304.8mm) apart, use three 3" (76.2mm) lag bolts for the upper mounting channel and three 3" (76.2mm)
lag bolts for the lower mounting channel. If the studs are 16"(406.4mm), 18" (457.2mm) or 24"(609.6mm) apart, use two 3"
lag bolts for the upper mounting channel and two 3" lag bolts for the lower mounting channel.
Si les rivets sont séparés de 12" (304,8 mm), utiliser trois tirefonds de 3" (76,2 mm) pour le canal d'installation supérieur et
trois tirefonds de 3" (76,2 mm) pour le canal d'installation inférieur. Si les rivets sont séparés de 16"(406,4 mm), 18" (457,2
mm) ou 24"(609,6 mm), utiliser deux tirefonds de 3" pour le canal d'installation supérieur et deux tirefonds de 3" pour le
canal d'installation inférieur.
Page 6
Step 10. Re-level the AM175.
Mounting Slot
Step 11. Using a 1/2" socket wrench, completely
Flat Washer
Upper Mounting Channel
5/16" Lag Bolt
1/2" Socket
Wrench
Repeat these steps to secure the lower mounting channel
to the wall.
tighten the two (2) upper lag bolts.
Do NOT over-tighten lag bolts when
attaching the mount to the wall. Improper
installation may result in personal injury or
damage to property.
Éviter
de trop serrer les tirefonds lors de la
fixation du support au mur. Une installation
incorrecte peut entraîner des blessures ou
des dommages matériels.
A minimum of two (2) wall studs must be
used in the installation of this product.
Un minimum de deux (2) ossatures murales à
claire-voie doit être utilisé lors de l'installa-
tion de ce produit.
There will be a total of four (4) mounting
points (2 for the upper mounting channel and
2 for the lower mounting channel).
Il y aura un total de quatre (4) points de
montage (2 pour le canal de montage de
haut et deux pour le canal de montage de
Installation Instructions