INSTALLATION, OPERATING INSTRUCTIONS AND OWNER'S MANUAL
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION OF YOUR
PLEASE RECORD THE SERIAL NUMBER ______ OF YOUR WHIRLPOOL AND SAVE THIS MANUAL
NOTE: These instructions are to be used along with the installation instructions for
WARNING - When using electrical products, basic
precautions should always be followed, including the
following:
1.
DANGER:
Risk of electrical shock.
Connect only to a circuit protected by a ground fault
circuit interrupter, (GFCI).
2.
Grounding is required. An equipment grounding
terminal is provided in the field wiring compartment.
To reduce the risk of electric shock, this terminal must
be connected to the grounding means provided in the
electric supply panel with a conductor equivalent in
size to the circuit conductors supplying the
equipment.
3.
Install this unit in accordance with the Canadian
electrical code, part 1 or the appropriate code in other
countries
4.
Install to permit access for servicing.
5.
Provide adequate ventilation for the motor to prevent
nuisance trips of the thermal overload protection.
INSTALLATION NOTES
Important: All Mirolin Acrylic Whirlpools receive a thorough
water test and are carefully inspected and packed for
shipment.You should check your unit for any problems.
Contact your dealer before installation.
Protect the bathtub and fittings from dirt and damage by
leaving the polyethylene protective film in place until
installation and other related construction are complete.
Caution: Do not lift a whirlpool bath by its plumbing.
Handle it by the bath shell only.
Access for servicing the pump and controls of the whirlpool
bath must be provided (Refer to specification drawings for
location). DO NOT remove or relocate the pump from its
factory-installed position. This position ensures proper
priming, drainage, and performance of the whirlpool system.
Relocating the pump will void the warranty.
NOTE: The unions for the piping at the pump are only to be
hand tightened. Check by hand that they have not loosened
during shipping.
DRAIN & OVERFLOW LEAK TEST
Test the installation after completing the plumbing, but before
enclosing the bath and finishing the surroundings. Fill the bath
with water and leave it for one hour to ensure that the
©
Copyright 2010
Mirolin Ind.
ACRYLIC WHIRLPOOLS
WHIRLPOOL HYDROMASSAGE BATHTUB
FOR FUTURE REFERENCE.
ACRYLIC BATHTUBS
The Copyright includes all content on the document
adjustment of the drain-overflow assembly is correct, and
that there are no leaks.
WHIRLPOOL FITTINGS LEAK TEST
Do not run the whirlpool pump unless the bath is filled
with water to a level at least 2" (50 mm) above the
whirlpool fittings. Press the tub-mounted air switch
control (A/S) to start the pump. Run the pump and jets for
10 minutes to ensure there are no leaks around the
whirlpool fittings. Press the air switch control (A/S) again
to stop.
Mirolin Industries Corp. will not be liable for any kind of
damages as a result of not water testing the unit prior to
use by end user.
MODELS WITH INTEGRAL APRON
Whirlpools with an integral apron have a removable
panel in the apron for access to the pump and motor.
Depending on the design of the whirlpool, the panel is
fastened to the apron by either of the following:
Strips of interlocking fabric (velcro) along the top
!
with plastic clips on the bottom (Figure 1).
Screws (Figure 2).
!
In either case, to remove panel follow instructions below:
Panel with strips of interlocking fabric: gently pull the
panel away starting from the top.
To replace the panel, position the removable panel onto
lower flange and press into place against the velcro pads.
REMOVABLE
PANEL
CLIP
APRON FRAME
1
Figure 1 - Removable Centre Panel
.
mirolin.com
VELCRO
2
3
1