INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
Important: Mirolin Acrylic Showers are carefully inspected
and packed for shipment. You should check your unit and if
there are any problems contact your dealer before
installation. Protect the shower from dirt and damage by
leaving the polyethylene protective film in place until
installation and other related construction are complete.
Follow Local Building Codes.
Tools and Materials Required
Tools: Tape Measure, Electric Drill, Drill Bit (3/16"), Level,
and Caulking Gun
Materials: Mildew Resistant Silicone Bathroom Caulking,
Drywall Screws and Shims (if required).
Caution:
Assembly and installation of this shower unit requires
2 persons.
General Installation Notes
Note: Dimensions are clear openings. Refer to specification
sheet for dimensions of shower unit and the chart below.
The Shower is to fit into formed recess as shown in
Figure 1 and Figure 2.
Clear opening is required with the flange outside of the
opening:
Framing
ROUGH IN
A
DIMENSIONS:
SH3
88" X 38"
88"
SH33
85 " X 38"
85 "
SH4
88 ½ " X 51"
88 ½"
SH43
85 ½" X 51"
85 ½"
A
B
G
E
C
©
Copyright 2010
Mirolin Ind.
MADISON 3
PLEASE RECORD THE SERIAL NUMBER _________ OF YOUR SHOWER
SAVE THIS MANUAL FOR FUTURE REFERENCE
B
C
D
86 ½ "
38"
35"
83 ½ "
38"
35"
87"
51"
36"
84"
51"
36"
F
D
FIGURE 1, FIGURE 2
LAYOUT DIMENSIONS
The Copyright includes all content on the document
MADISON 4
,
Inside dimension of the studded alcove are to be as
specified in Figure 1.
Follow Figure 2 as specified to ensure width is E"
between the 2" x 2" recessed studs. (See enlarged
detail.)
3-Piece Units
To facilitate moving through door ways 3-piece units
may be taken apart.
On the 3-piece units remove the 2 - 2"x2" wood blocks
on the side flange before installation. They are for
shipping only.
Shimming May Be Required
The unit will rest on the front edge and the two legs at the
rear of the unit. Shims may be required to level the
shower to ensure adequate drainage. Insert the bottom
section in the alcove and shim accordingly. Then
remove and assemble as per instructions.
The shower is fastened in place using dry wall screws.
Holes are to be drilled in the flange on both sides and
across the top. The holes are to be drilled by the installer,
installation illustrated in figures 3 and 3A.
If there is a gap at the seam on the front post, then shim
the flange as illustrated in Figure 3B.
E
F
G
35"
16"
19"
35"
16"
19"
48"
17"
25 ½ "
48"
17"
25 ½ "
2" x 4"
WOOD BLOCK
DRYWALL
.
mirolin.com
2" X 2"
WOOD BLOCK
DRYWALL
SCREW
3/8"
D
E
C
1

Publicité

loading

Sommaire des Matières pour Mirolin MADISON 3

  • Page 1 PLEASE RECORD THE SERIAL NUMBER _________ OF YOUR SHOWER SAVE THIS MANUAL FOR FUTURE REFERENCE Important: Mirolin Acrylic Showers are carefully inspected Inside dimension of the studded alcove are to be as and packed for shipment. You should check your unit and if specified in Figure 1.
  • Page 2 COUNTER SINK FIGURE 3A STUD SHIM FIGURE 3B FIGURE 3 - FASTENING WITH DRYWALL SCREWS FIGURE 4 - DRYWALL FINISHING Note: Remove the protective film from the tile flange before fastening. SNAP-FIT SYSTEM ASSEMBLY INSTRUCTIONS NOTE: To the Installer - Please remove all the shims from the Snap Fit extrusions of the unit prior to installation. The 3-piece Shower unit should be pre-assembled first prior to alcove installation.
  • Page 3: Preparation

    TESTING Ensure that the floor is level, correct if necessary. Location of Mirolin supplied drain for shower stalls is Test the installation after completing the plumbing, but before shown in Figure 1 & 2, to be assembled as in Figure 14.
  • Page 4: Important

    VEUILLEZ INSCRIRE ICI LE NUMÉRO DE SÉRIE _________________ DE VOTRE DOUCHE CONSERVER CE GUIDE POUR RÉFÉRENCE ULTÉRIEURE Structure IMPORTANT: Les douche Mirolin en acrylique sont inspectées et es dimensions intérieures de l'alcôve avec montants doivent être soigneusement emballées pour l'expédition. Vous devriez vérifier identiques à...
  • Page 5 COUNTER SINK ILLUSTRATION 3A Montant ILLUSTRATION 3B Mural Cale de Support ILLUSTRATION 4 FIXATION DU CLOISON ILLUSTRATION 3 - FIXATION DU VIS DE CLOISON Note: retirer le film protecteur du rebord pour carreaux de céramique avant fixation. DIRECTIVES D’INSTALLATION DU SYSTÈME SNAP-FIT NOTE : A l'Installateur - enlève s'il vous plaît tous les cales de support du Claquement les extrusions Capables de l'unité...
  • Page 6: Entretien

    La figure 1 et 2 illustre la localisation du drain fourni par Examinez l'installation après exécution la de la tuyauterie, mais avant Mirolin pour les cabines de douche et la Figure 14 indique d'enfermer la douche et finir les environnements.

Ce manuel est également adapté pour:

Madison 4Sh3l/rSh3ls/rsSh4l/rSh4ls/rsSh33l/r ... Afficher tout