Télécharger Imprimer la page

Toshiba RAS-B10PKVSG-E Manuel D'installation page 15

Masquer les pouces Voir aussi pour RAS-B10PKVSG-E:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
In Case of Indoor Unit Connect With 1:1 Outdoor Unit
Power supply cable
Power supply cable
connect to L N
Terminal block (L N 1 2 3)
Connecting cable
Connecting cable
connect to 1 2 3
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Connecting cable
Connecting cable
connect to L 2 3
Terminal block (L N 1 2 3)
Power Supply Input at Indoor Unit Terminal Block (Recommend)
Indoor Unit
Stripping length of the power
supply cable
10 mm
N
L
10 mm
Earth line
Power supply
cable
Stripping length of the
connecting cable
10 mm
3
10 mm
70 mm
Earth line
Connecting
cable
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor Unit
Stripping length of the
connecting cable
10 mm
3
2
L
10 mm
70 mm
Earth line
Connecting cable
Terminal block
Earth line
50 mm
Connecting
cable
70 mm
Earth line
50 mm
Terminal block
Earth line
50 mm
Connecting cable
13
Outdoor Unit
Connecting cable
Outdoor Unit
Power cord
Earth line
Earth line
Connecting cable
Power cord
EN
ES
Earth line
FR
IT
DE
PT
PL
CZ
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI

Publicité

loading