Cleaning about pellet tank. Clean with a vacuum cleaner to remove every residual of
•
combustion. Before cleaning let finishing the pellet inside the apparatus and remove the
plug. If necessary take away also the tank grate
External Cleaning.
•
This kind of operation has to be done when the stove is cold
Iron / Steel parts : clean with a duster with appropriate detergent.
−
Window / Ceramic parts : clean with a sponge with appropriate detergent and
−
dry with a duster.
Painted parts : clean with a duster and neutral soap than dry with a duster.
−
We recommend to execute a regular maintenance of the appliance, of the fumes exhaust
ducts and of the chimney. In case of a long time of non utilization of the appliance,
before lighting the stove, verify that fume exhaust ducts and chimney are not obstructed.
3.2
Ordinary maintenance (by qualify staff)
At least once a year a general control on the appliance should be effected by a
•
specialized technician.
It is advisable that every year a specialized after-sales service effects the following
•
maintenance operations:
Exhaust gas ducts cleaning;
−
Seat of exhaust gas motor cleaning;
−
Verification and eventually replacement of gaskets;
−
Chimney verification.
−