4.4.4 To change the head harness
The head harness can be ordered as a spare part only
as a complete harness.
• Snap the strap holders of the head harness off the
mask strap mountings. Fig. 16, 17.
• Check that the straps are not twisted and fit the new
head harness.
5. Technical specification
Classification according to ATEX-directive 94/9/EC
and IECEx Scheme
See paragraph 8, Approvals.
Inhalation resistance with Particle filter
≈ 44 Pa at 30 l/min.
Exhalation resistance
≈ 56 Pa at 160 l/min.
Materials
The material and pigments of the mask body are approved
for exposure to provisions, which minimizes the risk of
contact allergies.
All plastic parts are marked with material codes and
recycling symbols.
Shelf life
The equipment has a shelf life of ten years from the date
of manufacture which can be established by examining
the date wheel at the top of the outer mask body.
Size
Manufactured in one size.
Temperature range
• Storage temperature: from -20 to + 40 °C at a relative
humidity below 90 %.
• Service temperature: from -10 to +55 °C at a relative
humidity below 90 %.
• Service temperature when used together with fan SR
500 EX is -10 to +40 °C
Thread
Mask and filter adapter: Rd 40x1/7". EN 148-1:1999.
Weight
≈ 500 gram.
6. List of parts
The item numbers below refer to Fig. 1 at the end of
these instructions.
Item Part
No.
Full face mask SR 200 w PC visor
Full face mask w glass visor
1.
PC visor SR 366
1.
Laminated glass visor SR 365
2.
Mask body
3 . Upper frame half with screws
4 . Head harness, fabric
4.
Rubber head harness SR 340
5.
6.
7.
8.
9.
9.
9.
9.
9.
9.
9.
9.
10. Filter adapter SR 280-3
11. Seal for filter connection
12. Particle filter adapter SR 611
* Must not be used in potentially explosive atmosphere.
7. Key to symbols
8. Approvals
CE/EN
The SR 200 with polycarbonate visor is approved in ac-
cordance with EN 136:1998, class 3.
The plastic visor has been tested against EN 166:1995,
Ordering No.
class B.
The SR 200 with glass visor is approved in accordance
H01-1212
with EN 136:1998, class 2.
H01-1312
The SR 200 in combination with fan unit SR 500/SR 700 is
R01-1201
approved in accordance with EN 12942:1998, class TM3.
T01-1203
The SR 200 in combination with compressed air at-
-
tachment SR 307 is approved in accordance with EN
R01-1202
14594:2005.
R01-1203
The SR 200 in combination with fan unit SR 500 EX is
T01-1215
approved in accordance with EN 12942:1998, class TM3,
ATEX Directive 94/9/EC and the IECEx scheme.
Membrane kit
a) Exhalation membranes, two
b) Valve covers, two
c) Inhalation membranes, three
d) Dowels, two
Pre-filter holder
Pre-filter SR 221
Particle filter P3 R, SR 510
Gas filter A1, SR 217
Gas filter A2, SR 218
Gas filter AX, SR 298
Gas filter ABE1, SR 315
Gas filter ABE2, SR 294
Gas filter K1, SR 316
Gas filter K2, SR 295
Gas filter ABEK1, SR 297
Combined filter ABEK1-Hg-P3 R,
SR 299-2
Peel-offs SR 343, for plastic visor*
Peel-offs SR 353, for glass visor*
Spectacle frame for corrective
lenses SR 341, fig. 19
Welding Cassette SR 84, fig. 20*
Voice Amplifier SR 324, fig. 21*
Test adapter SR 370, fig. 22*
Storage box SR 344, fig. 23*
Carrier strap
ID-tag SR 368
Cleaning tissues SR 5226, box of 50* H09-0401
See user instructions
Date wheel
CE approved by INSPEC Certification Ltd
R01-1204
-
-
-
-
R01-0605
H02-0312
H02-1312
H02-2512
H02-2012
H02-2412
H02-3212
H02-3312
H02-4212
H02-4312
H02-5312
H02-6512
H09-0212
R01-1205
T01-1223
T01-1204
T01-1205
T01-1201
T01-1212
T01-1217
T01-1206
T01-1214
R01-1206
R09-0101
31