9. RS 232 INTERFACE
The viewers of this series can incorporate optionally a RS-232 interface.
SPECIFICATIONS:
• RS-232 interface data weighing.
• ASCII code
• 8 Data bits
• Without parity
CONNECTOR: SUB-D TYPE 9 PINS
• Pin 2: Rx
• Pin 3: Tx
• Pin 5: GND
The data formats for the normal operations of weighing, counting mode and accumulation of total memory will be different.
Examples:
FRAME: WEIGHING MODE
,
Kopf 1
FRAME: PIECE COUNTING MODE
P
C
S
NORMAL OUTPUT
GS
Nº
Total
<CR> <LF>
<CR> <LF>
TO MAKE THE PARTS COUNTING, WILL BE PRINTED ON UNIT WEIGHT AND THE COUNT
GS
U.W.
PCS
<CR> <LF>
<CR> <LF>
RETRIEVING THE TOTAL WEIGHT STORED IN THE MEMORY OF ACCUMULATION, THE OUTPUT FORMAT IS:
***************
TOTAL
Nº
Peso
<CR> <LF>
<CR> <LF>
44
-/_
Kopf 2
:
12,340kg
GS for gross weight, NT for net weight and a unit of weight.
1
This number increases each time a new value will be stored in the
memory.
12,340kg
Total value stored in memory.
Includes 2 characters line change.
12,340kg
GS for gross weight, NT for net weight and a unit of weight.
123,4g/pcs
The average weight per piece counted by the balance.
100pcs
The total number of pieces counted.
Includes 2 characters line change.
It shows a line of stars
Includes 2 characters line change
5
21,455kg
Wiegedatum
QTY
USER'S MANUAL BR40
k
g
Wiegeeinheit
_
P
C
S
-QTY UNITS-
EN
EN
CR
LF
Terminator
CR
LF