The winter season
In the winter months, life in the pond is resting, so filtering is no longer necessary!
Protect the complete filter system from frost!
In autumn you should empty and clean the complete filter system.
Store all parts in a room free of frost over the winter.
Scope of Delivery / Spare Parts: (see Fig. B + C)
Item Designation:
Art.-No.:
1
Filter housing D
104/003324
2
Filter cover D
104/003325
5
Bulkhead D
104/003327
6
Housing connector Ø50
104/001722
7
Union nut 2"
116/000080
8
Gasket 2"
104/003342
9
Gasket 1"
104/001666
10
Gasket 1 1/4"
104/001667
11
Screw connection 1"
104/003357
12
Hose fitting 1 1/4"- Ø40/32/25
104/002647
13
O-ring 40x3
213/000024
14
Filter brushes Ø10x18
162/002430
15
Filter sponge
162/003345
16
Filter granules
124/000162
17
Reducer bushing 1"- 1 1/4"
104/000826
18
Adapter
104/002989
19
Ball valve 1"
116/000105
20
Screw M5x16 1
14/000034
21
Nut M5 1
14/000035
22
Pond pump WP 3300 S
156/003344
23
UVC lamp 15 W II
162/002718
24
Hose connector 11/4"- Ø40/32/25 104/003042
25
Reducer 1"-3/4"
104/003356
26
Bracket
104/003256
27
Nut M4 1
14/000012
50
Vortex chamber
104/002950
51
Vortex chamber cover
104/002951
52
Angle 1" 90°
104/003090
PLEASE APPLY IN WRITING TO THE FOLLOWING ADDRESS FOR SPARE PARTS OR CONTACT YOUR DEALER!
T.I.P. - SERVICE
Siemensstraße 17 · D - 74915 Waibstadt · FAX +49 7263/912585
service@tip-pumpen.de
Number
Number
MTS 30000 UV25
Vortex chamber
1
-
1
-
2
1
1
-
1
-
1
-
3
1
1
-
3
1
1
-
1
-
6
-
2
-
7 l
-
2
-
1
-
3
1
2
-
2
-
1
-
1
-
1
-
1
-
2
-
4
-
-
1
-
1
-
1
20
GB
Please read these instructions thoroughly, before using the UV-C unit!
Use
This UV-C unit is suitable for use in garden or fish ponds helping to clear polluted pond water.
It is not allowed to use the unit in or on the side of swimming pools!
For all technical data please refer to the type plates.
Safety measures
- Cautio! UV-C radiation is dangerous to eyes and skin! Do operate the UV-C unit only inside the
casing. Translucent connections allow you to check easily and safely that the unit is working
properly.
- It may only be used in garden ponds and in their protection area, if the installations have been set up to
comply with the code's requirements. Please contact an electrician.
- The UV-C unit has to be connected to a regular safety plug socket through a circuit breaker (ground
fault circuit interruptor, 30 mA).
- Before use: Check whether mains connection and electrical box are intact.
- The mains connection of the electrical box cannot be replaced. If the connection is damaged the device has to
be scrapped.
- If the mains connection between electrical box and UV-C unit is damaged it must be replaced by the manufac-
turer or his customer service or similarly qualified personnel in order to avoid dangers.
- Mains voltage and type of current have to correspond to the data on the type plate of the electrical box.
- The connection box and the UV-C unit should be located in a water-protected area. They should be at least
3,5 m away from the edge of the pond (see fig. I + II)
- Keep the plug dry!
- Pull out mains plug before starting to work on the UV-C unit, garden or fish pond. (Disconnect the
electrical box.)
- It is not allowed to run the UV-C unit when people are inside the water!
- Do never immerse the UV-C unit in water and make sure that the unit may not be flooded.
- Do never hang up or transport the UV-C unit by the cables.
- Avoid exposure to intense sunlight.
Start-up (see fig. I + II)
Important! Make sure that water always passes through the UV-C unit during operation.
Otherwise the unit could be damaged.
- You should only connect a pump with a max. delivery head of 10 m (1 bar).
- The water temperature should not exceed 35° C.
- Fasten the UV-C unit by means of the fixing stands (15) in a flood-proof position.
- The quartz glass tube (2) will be polluted by the pond water, thus reducing the UV-C performance.
This needs cleaning of the quartz glass tube (2) at regular intervals according to the degree of pollution.
- The UV-C lamp (1) has a rated life of approx. 8000 hours. After that it should be replaced, at least at the end of
one season (from March till October).
- We recommend you to run the unit 24 hours a day (continuous use). Avoid frequent switching (on/off).
This will reduce the lifetime of the UV-C lamp.
- Connect the translucent connections of the UV-C unit to your filtration system (hoses, pumps, filters...).
You should use only flat gasket rings for sealing your hose connectors, joining rings or sealing liquids may
damage the threaded connection.
- The connections may be turned against each other. For this purpose you should loosen and remove the
union nuts (11) of the red end caps (9) and slightly loosen the pressure plates (6) as well (see fig. III).
Cleaning and changing the lamp (see fig. III)
Dismantling
1. Follow the safety measures.
2. Disconnect the UV-C unit and secure against reclosing.
3. Pour out the water completely.
4. Loosen the two union nuts (11) of the red end caps (9) and draw off both pieces.
5. Remove the lampholders (3) from the UV-C lamp (1).
6. Pull the UV-C lamp (1) out with caution and replace it, if necessary. Old lamps should not be broken and
disposed of in the household refuse. Please contact your local company responsible for refuse collection.
7. Turn out the pressure plates (6) and draw the O-rings (7) from the quartz glass tube (2).
8. Remove the quartz glass tube (2) carefully and clean it thoroughly. Do avoid using any sharp instruments.
If the quartz glass tube (2) or the O-rings (7) are damaged, they should be replaced.
21