GAS INPUT FOR DIRECT VENT FIREPLACE
CONVERTED TO PROPANE GAS:
DVCT36CBP95 - 39,500 BTU per hour
The direct-vent gas fireplace when converted to Propane
INSTRUCTIONS FOR CONVERSION
1. If the fireplace is installed, turn OFF gas and electric
supply to fireplace before making gas conversion.
Allow fireplace to cool completely.
2. Remove barrier screen, glass door, logs and embers,
and liners (see Homeownerʼs Manual and Liner
Instructions).
3. Remove front and rear burners by removing screws on
left and pulling out towards left side. See Figure 2.
4. Remove (2) screws holding pilot assembly to burner pan.
This will allow pilot assembly to drop. See Figure 3.
Page 2
Figure 1
Figure 2
.
Figure 3
Empire Comfort Systems Inc. • Belleville, IL
Gas will have a manifold pressure of approximately 10.0
inches w.c. (2.49 kPa) at the valve outlet with the inlet
pressure to the valve from a minimum of 10.8 inches
w.c. (2.68 kPa) for the purpose of input adjustment to a
maximum of 14.0 inches w.c. (3.484 kPa).
5. Remove (2) screws holding burner base in place. Lift
burner base out of firebox. See Figure 4.
6. Use needle-nose pliers to remove targets and discard.
See Figure 5.
7. Use a 7/16 inch deep socket set to remove front and
rear orifices.
8. Use a 7/16 inch deep socket set to install orifice marked
"1.45" in rear orifice holder and "#56" in front orifice holder.
Figure 4
REAR
REAR
FRONT
FRONT
Figure 5
REAR
REAR
FRONT
FRONT
Figure 6